Setting Procedures Of Vacuum Sensor - Panasonic CM602-L Reference Manual

Table of Contents

Advertisement

Setting procedures of vacuum sensor (Example: For CM301)
Make the setting on each beam. (Two indicators need to be set.)
<Reference vacuum uptake value check>
EJM4A-E-RMA01-A01-00
CM602-L
Reference Manual
1.
Attach 1003 nozzles to each head.
∗ Use the nozzles without orifices.
2.
Select the channels (1ch, 3ch) to be set,
using
Each channel's function
3.
Press
• When it is reset, 0 is indicated.
• It is carried out with a vacuum OFF.
4.
Turn ON a vacuum in the output check.
5.
Read the indication on the vacuum
sensor.
1.4 Other Specifications
and
keys.
1ch
Head A
Nozzle-off detection
2ch
Head A
Pickup miss
detection
3ch
Head B
Nozzle-off detection
4ch
Head B
Pickup miss
detection
for three seconds or more.