D9068 | Operation and Installation Guide | Appendix C: Fire Communicator Report
.
Fault
System
Trouble
IA 11
Programming
Refer to Note 1 through Note 9 on page 56
2
* In Modem IIIa
, the D9068 uses Communications Fail to report a Data Lost event. The D9068 reports an
Equipment Fail and Equipment Fail Restore with Condition 006 to report an actual Communications
Fault.
Table 14: Reporting Summaries (Continued)
Report
SIA
Description
Code
System
Restore
IR 11
Programming
Serial
Communication
YC
Fault
Serial
Communication
YK
Restore
Refer to Note 1 through Note 9 on page 56.
Table 15 identifies equipment fail conditions. These conditions appear as a System
Trouble in Contact ID.
On a D9068 that is serially connected to a Bosch Analog FACP, Table 15 only applies
when the reported address
(C for Contact ID, SDI for Modem IIIa
is more than 100, the reported event is a peripheral fault. Refer to Appendix F:
D8024/D10024/D10024A Analog FACP Operation on page 64 for more information.

Table 15: Equipment Fail Conditions

Code
Event
Dialer Trouble
2
Input
System Trouble
5
Keypad
6
Comm Fault
System Trouble
11
Programming
12
Network Failure
13
FACP Programming
FACP Config RPS
14
Fail
FACP Processor
15

Reset

FACP Unresolved
16
IRQ
FACP Ground
17
Fault
FACP Loop Wiring
18
Fault
Bosch Security Systems, Inc. | 3/13 | F01U071094-07
Restoral
Equipment
1 300 aa
Failure
011
Condition
Point-Related Events
SIA
Contact
Description
ID Code
Equipment Fail
3 300 aa
Restoral
011
Communications
1 350 aa
Fail
000
Communications
6 350 aa
Restoral
000
) is less then 100. If the reported address
2
Data in
Address Field
Point
N/A
N/A
N/A
Control panel
address
Control panel
address
Control panel
address
Control panel
address
Control panel
address
Control panel
address
Control panel
address
System
FD
Trouble
Contact ID
Description
System
Trouble
Communication
Trouble
Communication
Trouble
Restoral
Generated
Description
By
A point configured for Fault on
Dialer
Open or Fault on Short was
tripped.
The programming keypad was
Dialer
connected to the D9068.
Dialer
A Comm Fault occurred.
Programming was entered on the
Dialer
D9068.
Control
A control panel fail or restore
panel
occurred.
The control panel was left in the
Control
panel
Programming Mode.
Control
The RPS Config failed.
panel
Control
The processor reset.
panel
Control
There is an unresolved interrupt
panel
request (IRQ).
Control
There is a ground fault.
panel
Control
There is a fault in wiring loop.
panel
Equipment Fail Cond
= 011
4/2
2
Code
Modem IIIa
Default
Description
Values
Equipment
ED
Restoral Cond = 011
FD
Comm Fail, RG = 1
Comm Fail
ED
Restr = RG1
Summary
59