DISPLAY UNIT for (Energy Measuring Unit)
Model:EMU4-D65
Instruction manual (Simplified edition)
● Be sure to read this instruction manual and this equipment detail manual before use.
● After reading on, you keep it in a safe place where you can be seen at any time, please read when needed.
● Please send this instruction manual to the end user.
● You can download User's manual of this Unit from the following site.
● http://www.mitsubishielectric.com/fa/worldwide/index.html
1. Feature
 The monitoring of measured data at Mitsubishi Energy Measuring Unit is possible.
 Easily viewable by backlight and dot matrix LCD display.
 Multiple circuit monitoring is possible using only one unit.
 It is possible to switch the display language (Japanese / English) in the setting.
2. Confirmation of contents of package
Each unit comes with the following accessories. Check for missing ones.
Main Body x 1
3. Precautions concerning working environment and conditions
3.1 Working environment and working conditions
This equipment, based on the assumption that it is used in the pollution degree 2 (Note 1) environment.If it is used in other degree of contamination,
please do the protection on the device side to be incorporated.Measurement categories for measuring circuit for this equipment is CATⅢ (Note 1).
The overvoltage category of the auxiliary power supply circuit (MA, MB) is CATⅢ (Note 1).Do not use the unit in any of the following places. Doing so
may cause malfunction or reduction in service life.
⋅ Place where the ambient temperature exceeds the working temperature range(−5°C -
+55°C)
⋅ Place where the humidity exceeds the humidity range (30% - 85%RH) or
condensation occurs
⋅ Place with much dust, corrosive gas, salt or oily smoke
⋅ Place where the unit may be exposed to rain or drops of water
⋅ Place where metallic particles or inductive substances are dispersed
This equipment is the open type equipment. (Electric shock protection of the instrument was designed to perform housed in another apparatus
equipment) Please use are housed in a control panel etc. Always. For notes on when to adapt the equipment that you have configured in this
equipment to the EMC Directive, please refer to the Instruction Manual (Detail edition).
Note 1:For a definition of pollution degree and the measurement categories, please refer to the EN61010-1 / 2010.
3.2 Preparation before using
• An installation place should keep the working environment and working conditions.
• The protection sheet for the crack prevention is put on the display part. Before use
this product, remove the protection sheet. It is not unusual, although a LCD display
part may light up by generating of static electricity in case it removes. After a while,
it disappears by natural electric discharge.
• Following setup is need before using EMU4-D65.
The one always in one system is the Master set, Other display unit of, please to Slave configuration.
(The wrong setting and it does not work)
3.3 Installation and connection
• Before installing and connecting the unit, read the instruction manual without fail. For safety, the unit shall be installed and connected by experts in electrical work.
• When threading and wiring, take utmost care that cuttings and wire pieces do not enter the unit.
Caution
• Connect the wires carefully checking the wiring diagram. Improper wiring can cause unit failure, fire and electric shock.
• Perform wiring work in a dead state. Do not wire the unit in a live state. Doing so can cause electric shock, ground fault, unit failure and fire.
3.4 Precautions for Use
• This unit cannot be used for deal and proof of electric energy measurement stipulated in Measurement Act.
• EMU4-PX4 and EMU4-AX4 is supported with later version 2.00. For information about how to determine the version, please refer to 7.2.7.
• Use this unit within the ratings specified in this manual. If it is used outside the ratings, it may cause not only malfunction or failure but also fire burnout.
• Do not disassemble or modify this unit. It may cause failure, malfunction, injury or fire.
Caution
• Do not touch the live part such as connection terminal. It may cause electric shock, electric burn injury or burnout of the device. If any exposed conductor is found, stop the operation
immediately, and take an appropriate action such as isolation protection.
3.5 Maintenance Precautions
• Use a soft dry cloth to clean off dirt of the unit surface. Do not let a chemical cloth remain on the surface for an extended period of time nor wipe the surface with thinner
or benzene.
• Check for the following items to use this unit properly for long time.
(1) Daily maintenance
(a) No damage on this unit
(2) Periodical maintenance (Once every 6 months to 1 year)
• No looseness with installation and wire connection
Do periodical maintenance under the electric outage condition. Failure to do so may cause electric shock, failure of the unit or a fire. Tighten the terminal regularly to prevent a fire. In case
Caution
a display unit is attached to a sensor unit, get off the display unit during maintaining or tightening terminals.
3.6 Storage Precautions
To store this unit, turn off the power and remove wires, and put it in a plastic bag.
For long-time storage, avoid the following places. Failure to follow the instruction may cause a failure and reduced life of the unit.
• Places the Ambient temperature exceeds the range -10°C - +60°C.
• Places the Relative humidity exceeds the range 30% - 85% or places with dewfall.
• Dust, corrosive gas, saline and oil smoke exist.
• Places the average daily temperature exceeds 35°C.
Connection cable x 1
(Simplified edition) x 1
(b) No abnormality with LED
EMU4-D65
Instruction manual
⋅ Place where the daily mean temperature exceeds 35°C
⋅ Place with much vibration or impact
⋅ Place exposed to direct sunlight
⋅ Place with strong electromagnetic field or much foreign noise
⋅ Place where the altitude is over 2000m
(c) No abnormal noise, smell or heat
• Vibration and impact exceed the specifications.
• Places exposed to rain, water drop or direct sunlight.
• Places metal fragments or conductive substance are flying.
- 1 -
This
product
dedicated
product
Mitsubishi Energy Measuring Unit
(EcoMonitorPlus, EcoMonitorPro)
and Mitsubishi Measuring Unit for
MDU Breakers (MDU2). It can not
be used for other purpose.
Switching board
Installation screw x 2
Please use after removing the
protection sheet.
is
the
optional
only
for

Advertisement

loading

Summary of Contents for Mitsubishi Electric EMU4-D65

  • Page 1 After a while, it disappears by natural electric discharge. • Following setup is need before using EMU4-D65. The one always in one system is the Master set, Other display unit of, please to Slave configuration.
  • Page 2: Part Names And Functions

    3.7 Disposal Precautions When disposing of this unit, treat it as industrial waste. 3.8 About packaging materials and this manual For reduction of environment load, packaging materials are produced with cardboard, and this manual is printed on recycled pa per. 4.
  • Page 3: Connection Method

    Extension method of connecting cable ■1-to-1 Connection example Energy Measuring Unit (1) Remove the trunking connector EMU4-HM1-MB MODEL Display unit (EMU4-D65) Energy Measuring Unit To the socket To the socket “DISPLAY” “IN 1” Remove depressing a lock (2) Insert the extension cable, and connect the connector Connection cable (bundled in this product)...
  • Page 4 7.2 Setup about rating, clock and display unit in the case of the model to connect the EMU4-**. (Setup mode) 7.2.1 Measuring setup … Setup the measuring condition of the energy measurement unit that is connected. EMU4-PX4 is not set. Screen Operation Note...
  • Page 5 Screen Operation Note 5-2. (1) Push the ▲ or ▼ key, and select the display mode. [DISP.Mode]:Wh+A+4⇔Harmonics⇔ [DISP.Mode] *In case of the model EMU4-BM1-MB , the (2) Push the / Phase key. “ Wh+A+4 Harmonics” not be displayed. (3) Transition to the following screen by the selection of measurement mode. Harmonics Wh+A+4…In addition to the active energyand current, [Wh+A+4] setting →...
  • Page 6 Screen Operation Note 7(2) Setup the demand time EMU4-LG1-MB ( ) 7 ( 2 ) -1 (1) In 7(2)-1, push the ▲ or ▼ key, and move the cursor to [Demand]:0sec⇔5min⇔6min⇔7min⇔8min⇔9min⇔ [Measure] the “6 Demand”. 10min⇔11min⇔12min⇔13min⇔14min⇔ 4 DISP.Mode 15min⇔20min⇔25min⇔30min⇔ (2) Push the / Phase key and 5 MEA.Mode Demand...
  • Page 7 Screen Operation Note 11-3. High SENS mode (1) Push the ▲ ▼ + - key, and change the Ior difference converted [DIF.Ior]:0.00~100.00mA [DIF.Ior] reference value. (2) Push the / Phase key,and confirm the setting value. 0.00 mA Low SENS mode (3)...
  • Page 8 Screen Operation Note 12-17. (1) Push the ▲ ▼ + - key, and change the scalling upper limit, lower [Upp]:-32767~32767(4095) [Scaling] [Low]:-32767~32767(0) limit, and unit. Upp.: 04095 [Unit]:Non⇔A⇔mA⇔kA⇔V⇔kV⇔W⇔kW⇔MW⇔Hz⇔N⇔ (2) Push the / Phase key, and confirm the setting value. Low.: 00000 kN⇔Pa⇔kPa⇔MPa⇔C⇔deg⇔%⇔...
  • Page 9 Screen Operation Note 2 Setup input EMU4-HM1-MB, EMU4-PX4 ( ) 2-1. (1) In 2-1, Push the ▲ or ▼ key , and move the cursor to the ”1 Input”. [I/O] (2) Push the / Phase key. Input (3) 2-2 will be displayed. 2 OP.Time 3 Output 2-2.
  • Page 10 Screen Operation Note 3 Setup the operation time measurement All models except for EMU4-LG1-MB ( ) 3-1. (1) In 3-1, Push the ▲ or ▼ key, and move the cursor to the [OP.Time]:Off⇔On⇔ [I/O] “2 OP.Time”. 1 Input EMU4-HM1-MB (2) Push the / Phase key.
  • Page 11 Screen Operation Note 5 Save the settings 5-1. 1 Save → Save settings and return to (1) After setting all of the items, push the Setup key. the operation mode. Quit Setup (2) 5-1 will be displayed. 2 Not Save → Discard the changes and Save (3)...
  • Page 12 7.2.4 Logging setup-the settings for the logging ID (Set only EMU4-BM1-MB, EMU4-HM1-MB, EMU4-LG1-MB connected the EMU4-LM.) Screen Operation Note 1 Transition to the setup mode 1-1. (1) Push the Setup key in operation mode. [ Setup ] (2) 1-1 will be displayed. 2 I/O (1)...
  • Page 13 Push the Circuit key → To 1-2 MODEL: EMU4-D65 7.3 In the case of the model EMU2-** and the model MDU2-**, to be connected, the settings for measurement, clock, display.(Setup mode) 7.3.1 Measuring setup … Setup the measuring condition of the energy measurement unit that is connected.
  • Page 14 △ △) Screen Operation Note 5 Setup the measurement mode EMU2-RD□- , MDU2-□- ( 5-1. (1) In 5-1, Push the ▲ or ▼ key, and move the cursor to the “4 Measure”. [Measure] (2) Push the / Phase key. 2 V rate (3)...
  • Page 15 7.3.2 Clock setup-the settings for the clock. Screen Operation Note 1 Transition to the setup mode (1) Push the Setup key in operation mode. △ △, △) (2) 2-1 will be displayed. 2 Clock setup EMU2-HM1- , EMU2-VS1-P, EMU2-RD□- MDU2-□- (...
  • Page 16: Outline Drawing

    8. Outline drawing ■ Display Unit main body (EMU4-D65) ■ Display unit connection cable 1000mm 500mm 500mm ▲ To “DISPLAY” socket of Trunking connector To “IN 1” socket of ▼ Energy Measuring Unit Display Unit IEC rail fitting unit 9. Specifications...