Mitsubishi Electric MELSEC Q Series Programming Manual page 65

Structured. fundamentals
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

• The following figure shows the examples of 32-bit index setting using 'ZZ' and their actual processing devices. (With the
setting of Z0 (32 bits) =100000 and Z2 (32 bits)=-20)
Ladder example
X0
DMOV
EN
K100000
s
DMOV
EN
K-20
s
X1
MOV
EN
ZR1000ZZ0
s
• Functions that can use 'ZZ'
32-bit index settings using 'ZZ' can be used in the following functions.
No.
Description
1
Device specification with an instruction in a program
2
Monitoring device registrations
3
Device test
4
Device test with an execution condition
5
Setting monitoring conditions
6
Sampling trace (trace point (device specification), trace target devices)
7
Data logging function (sampling interval (device specification), logging target data)
ZZn cannot be used individually such as 'DMOV K100000 ZZ0'. When setting a value to index registers to
specify a 32-bit index setting using 'ZZ', set a value to Zn (Z0 to Z19).
ZZn cannot be entered individually in the functions.
■32-bit index setting for FXCPU
Combine index registers V (from V0) and Z (from Z0) for a 32-bit index setting.
V is used for high order and Z is used for low order. With the combination of the specified Z and the corresponding V, the
device can be used as a 32-bit register.
Note that the index setting is not applied by specifying the high order V.
Example: When specifying Z4, V4 and Z4 are used as a 32-bit register.
Setting value
Z0
Z1
Z2
Z3
Z4
Z5
Z6
Z7
ENO
Z0
d
ENO
Z2
d
ENO
D13000Z2
d
Index register
V0, Z0
V1, Z1
V2, Z2
V3, Z3
V4, Z4
V5, Z5
V6, Z6
V7, Z7
Actual processing device
X1
MOV
EN
ENO
ZR101000
s
d
Description
ZR1000Z0
ZR(1000+100000)
D13000Z2
D(30-20)
D12980
4 PROGRAM CONFIGURATION
D12980
ZR101000
4.6 Index Setting
4
63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec f seriesMelsec l series