Inspection and maintenance
7. or remove the screws (8) at the intermediate
adapter (9) and remove the latter from the
service unit by pulling it downwards.
8. Check whether or not the new service unit (5)
goes with the control unit (1).
(model designation and colour of the arresting
hook (2)).
9. Installation of the new service unit (5) in reverse
order.
Installation of the control unit on the service unit:
1. Check whether or not the service unit (5) goes with
the control unit (1) (model designation and colour
of the arresting hook).
2. Check whether or not the sealing mat (11) and the
contact springs (13) are clean, dry, and free from
impurities.
3. Introduce the sensor (12) into the sensor tube plate
(14).
4. Hang the hook (15) of the control unit (1)
in the sensor tube plate (14).
5. Press the control unit (1) against the service unit
(5) and snap into place.
Start-up subsequent to maintenance measures:
Always carry out prior to the start-up:
Leak test of the screwed connector
Check of the electrical connections
Check of the correct engagement of the control unit