Technical Data - Beko BEKOMAT 32U Instructions For Installation And Operation Manual

Condensate drains
Table of Contents

Advertisement

5

Technical data

min./max. operating pressure
min./max. temperature
Condensate inflow
Condensate outflow
Condensate
Housing
Weight (empty)
This product has been tested to the requirements of CAN/CSA-C22.2 No. 61010-1-12, third edition, inclu-
ding a later version of the same standard incorporating the same level of testing requirements.
Max. performance for the "blue" climate zone – see also Chapter "Climate zones and performance data"
max. compressor performance
max. refrig.-dryer performance
max. filter performance
BEKOMAT® 32U
0,8...16 bar (12...230 psi)
+1...+70 °C (+34...+158 °F)
G ½ (NPT ½) internal
max. screw-in depth 13,5 mm (½")
G ¼ Ø 8 ... 10 mm hose connector
oil-contaminated + oil-free
aluminium + plastic, glass fibre-reinforced
1.0 kg (2.2 lbs)
5 m³/min (175 scfm)
10 m³/min (350 scfm)
50 m³/min (1750 scfm)