Ethernet Connections; Camera Connections - Bosch MIC IP fusion 9000i Installation Manual

Hide thumbs Also See for MIC IP fusion 9000i:
Table of Contents

Advertisement

MIC IP fusion 9000i
9.3

Ethernet Connections

Caution!
Ethernet cables must be routed through earth-grounded conduit capable of withstanding the
!
outdoor environment.
Cable Type
Maximum Distance
Ethernet
Terminal Connector
High PoE (95 W)
Note: Consult the National Electrical Code (NEC) or other regional standards for cable
bundling requirements and limitations.
9.4

Camera Connections

All electrical and data connections from the camera are made from the connectors in the base
of the camera.
Figure 9.1: MIC9000 connectors
1
Chassis (Earth) ground wire (18 gage) with connector lug
2
24 VAC power wires (24 gage) to Pins 4 and 5 of connector labeled P107 in
VG4-A-PSU1 or VG4-A-PSU2 (if not using a High PoE network)*
3
RS-485 connections for communication to / from the MIC-ALM-WAS-24 or other
device providing legacy serial protocol signals
4
RJ45 (Cat5e/Cat6e) connector (male) (supporting High PoE) for power and
communication between a Bosch High PoE Midspan
5
Audio wires (twisted pair cable recommended)
Bosch Security Systems
Cat5e/Cat6e Ethernet (Shielded Twisted Pair (STP)) (directly to the
camera, or to a network switch between the camera and the network)
Note: Cat5e/Cat6e Shielded Twisted Pair (STP) cable is required in
order to meet European regulatory EMC standards.
100 m (330 ft)
10BASE-T/100BASE-TX, auto-sensing, half/full duplex
RJ45, Male
Use a midspan sold by Bosch, or a midspan that is offered as a
compatible alternative.
Description
Installation Manual
Connections | en
Wire Color
Green
Line (L) = Black
Neutral (N) = White
+ = Purple
- = Yellow
GND = Brown
Audio IN + = Red
Audio IN - = Light blue
Audio OUT + = Orange
Audio OUT - = Dark blue
2018.09 | 1.1 | F.01U.334.820
27

Hide quick links:

Advertisement

Table of Contents
loading