Technical Specifications
The aggregator is an I/O module and installed with the Dell PowerEdge FX2 server chassis for
communication.
NOTE: Replace the battery only with the same or equivalent type. Dispose of the batteries according
to the manufacturer's instructions.
Table 3. Environmental Parameters
Parameter
Operating temperature
Storage temperature
Relative humidity
Storage humidity
Maximum thermal output
Maximum altitude
Operating
Storage
Table 4. Power Requirements
Parameter
Power supply
Maximum current draw per system
Maximum power consumption
IEEE Standards
The aggregator complies with the following IEEE standards:
•
802.3 CSMA/CD
•
802.3u 100BaseTx
•
802.3z (1000BaseSX)
•
802.3z/ab 1000BaseT
•
802.3ap 10GBase-KR
•
802.3x flow control
Technical Specifications
Specifications
20 °C/h (36 °F/h)
-40° to 158°F (-40° to 70°C)
5% to 95% RH with 33 °C (91 °F) maximum dew
point. Atmosphere must be non-condensing at all
times.
475 BTU/hr
3048 m (10,000 ft)
12000 m (39,370 ft)
Specifications
90–264 VAC 50/60 Hz
10A per power supply
1920W (high Line) 900 (low line)