11 Service Position
Note: For description of the disassembly procedures, see
the Section 10.
11.1. Checking of Panel P.C.B. and
LCD P.C.B.
Step 1 Remove Top Cabinet.
Step 2 Remove Front Panel Unit.
Step 3 Remove the Panel P.C.B. and the LCD P.C.B..
Step 4 Positioned the Panel P.C.B. and LCD P.C.B. on the
insulated material as shown.
Step 5 Attach 17P FFC at a connector (CN2000) on the Main
P.C.B..
Step 6 Panel P.C.B. and LCD P.C.B. can be checked at dia-
gram shown.
11.2. Checking and Repairing of
Main P.C.B. (Side B)
Step 1 Remove Top Cabinet.
Step 2 Remove Rear Panel.
Step 3 Remove Main P.C.B..
Step 4 Remove 2 screws.
Step 5 Lift up the Main P.C.B. as arrow shown.
Step 6 Attach 13P Cable at a connector (CON2) on the SMPS
Module.
Step 7 Attach 17P FFC at a connector (CN2000) on the Main
P.C.B..
Step 8 Attach 10P FFC at a connector (CN8251) on the main
P.C.B..
Step 9 Attach 24P FFC at a connector (FP8201) on the Main
P.C.B..
Step 10 Side B Main P.C.B. can be checked at diagram shown.
37