Magmaster Connection - ABB CalMaster2 Instruction Manual

Tests the integrity of a flow metering system by altering a number of flow measurement parameters and measuring the values returned from the flow measuring system.
Hide thumbs Also See for CalMaster2:
Table of Contents

Advertisement

Field and Software Tools
CalMaster2 and CheckMaster

3.2 MagMaster Connection

To enable a MagMaster system to be tested by the CalMaster2 it may be necessary to fit a small
adaptor board (see Section 3.2.1, page 10) to the MagMaster.
Note. The newer series VKH MagMaster does not need to have this adaptor board fitted as one
is already incorporated into its design.
Once the adaptor is fitted to the MagMaster transmitter, the CalMaster2 can be connected easily to
the transmitter for testing at any time.
Extra adaptor kits are available (part no. WADX0089).
To enable a hard-wired MagMaster system to be tested by the CalMaster2 it may be necessary to fit
a small adaptor board (see Section 3.2.1, page 10) to the MagMaster.
A
Fig. 3.1 Removing the MagMaster Covers
To remove the MagMaster covers:
Slide the cover down A.
1.
Pull out slightly and slide off B.
2.
Slacken the captive screws C.
3.
Remove the protective cover D.
4.
IM/VCM2 Issue 6
D
B
3 Installation
C
9