Reliability Features - Huawei MU609 Hardware Manual

Hspa mini pcie module
Hide thumbs Also See for MU609:
Table of Contents

Advertisement

HUAWEI MU609 HSPA Mini PCIe Module
Hardware Guide

5.5 Reliability Features

Table 5-9 lists the test conditions and results of the reliability of the MU609 module .
Table 5-9 Test conditions and results of the reliability of the MU609 module
Item
Stress
Low-temperature
storage
High-temperature
storage
Low-temperature
operating
High-temperature
operating
Damp heat
cycling
Thermal shock
Issue 03 (2014-12-04)
Test Condition
Temperature: –40ºC
Operation mode: no
power, no package
Test duration: 24 h
Temperature: 85ºC
Operation mode: no
power, no package
Test duration: 24 h
Temperature: –20ºC
Operation mode:
working with service
connected
Test duration: 24 h
Temperature: 60ºC
Operation mode:
working with service
connected
Test duration: 24 h
High temperature: 55ºC
Low temperature: 25ºC
Humidity: 95%±3%
Operation mode:
working with service
connected
Test duration: 6 cycles;
12 h+12 h/cycle
Low temperature:
–40ºC
High temperature: 85ºC
Temperature change
interval: < 20s
Operation mode: no
power
Test duration: 100
cycles; 15 Min+15
Min/cycle
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Electrical and Reliability Features
Standard
Sample size
JESD22-
3 pcs/group
A119-C
JESD22-
3 pcs/group
A103-C
IEC60068
3 pcs/group
-2-1
JESD22-
3 pcs/group
A108-C
JESD
3 pcs/group
22-A101-
B
JESD22-
3 pcs/group
A106-B
Results
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok
42