Node Example 3; Node Suggested Action 3 - HP 3PAR StoreServ 7000 Troubleshooting Manual

Hide thumbs Also See for 3PAR StoreServ 7000:
Table of Contents

Advertisement

cli% showbattery
Node PS Bat Serial
3
0
0 100A300B OK
3
1
0 12345310 Failed

Node Example 3

Component -Identifier- --------------Description----------------
Node
node:3
the last 30 days

Node Suggested Action 3

The indicated battery has not been tested in the past 30 days. A node backup battery is tested
every 14 days under normal conditions, but if a battery is missing, expired, or failed, it is not
tested. In addition, the other battery connected to the same node is not tested because testing it
would cause loss of battery backup to the node, and the system does not allow that. An untested
battery has an Unknown status in the showbattery -s output. Use commands such as
showbattery, showbattery -s, showbattery -d, and showbattery -log.
showbattery -s
Node PS Bat -State-- -Detailed_State-
0
0
0 OK
0
1
0 Degraded Unknown
Examine the date of the last successful test of that battery. Assuming the comment date was
2009- 1 0- 1 4, the last battery test on Node 0, PS 1, Bat 0 was 2009-09-10, which is more
than 30 days ago.
showbattery -log
Node PS Bat Test Result Dur(mins) ---------Time----------
0
0
0
0
0
0
0
1
0
0
1
0
showbattery
Node PS Bat Serial
0
0
0 83205243 OK
0
1
0 83202356 Degraded
PD
Displays Physical Disks (PDs) with states or conditions that are not optimal:
Checks for failed and degraded PDs
Checks for an imbalance of PD ports, for example, if Port-A is used on more disks than Port-B
Checks for an Unknown Sparing Algorithm. For example, when it hasn't been set
Checks for disks experiencing a high number of IOPS
Reports if a servicemag operation is outstanding (servicemag status)
Reports if there are PDs that do not have entries in the firwmare DB file
-State-- ChrgLvl(%) -ExpDate-- Expired Testing
Node:3, Power Supply:1, Battery:0 has not been tested within
normal
0 Passed
1 2009-10-14 14:34:50 PDT
1 Passed
1 2009-10-28 14:36:57 PDT
0 Passed
1 2009-08-27 06:17:44 PDT
1 Passed
1 2009-09-10 06:19:34 PDT
-State-- ChrgLvl(%) -ExpDate-- Expired Testing
100 07/01/2011 No
0 04/07/2011 No
100 04/07/2011 No
100 04/07/2011 No
Troubleshooting Storage System Components
No
No
No
No
37