Philips CM-150 CA Manual page 15

Control module for large scale architectural and media applications using flex nodes
Table of Contents

Advertisement

Make Luminaire Cable Connections
Flex strands from Philips Color Kinetics can use a detachable leader cable, or the
strands can be connected directly to a CM-150 CA, Surface Mount, 3-Wire control
module. Leader cables range from 305 mm (1 ft) to 30.5 m (100 ft), while Flex
strands range from 152 mm (6 in) to 3.7 m (12 ft) distance from the connector to the
first node.
Surface Mount Installation
1. Remove the end caps.
2. Plug leader cable or the Flex strand into the CM-150 CA, and secure
the connection.
4-wire output
DIN Rail Mount Installation
1. Strip 5 mm (0.2 in) of insulation from the wires. If using stranded wire, twist each
wire tight to secure the wire threads.
2. Run a leader cable to the top of the CM-150 CA housing.
3. Locate the luminaire three-wire or four-wire terminal block connectors inside the
CM-150 CA housing.
4. Securely install each wire in the appropriate terminal. Tighten the retaining screws
by hand with a screwdriver.
4-wire output
Data -
Data +
3-wire output
3-wire output
Data
CM-150 CA