Smart sensor gateway
Hide thumbs Also See for Cassia X1000:

Advertisement

T EC H N IC A L D O CUM E NT
Smart Sensor Gateway
Installation Manual
2 019 -0 2 -08
1 /16

Advertisement

Table of Contents
loading

Summary of Contents for ABB Cassia X1000

  • Page 1 — T EC H N IC A L D O CUM E NT Smart Sensor Gateway Installation Manual 2 019 -0 2 -08 1 /16...
  • Page 2: Table Of Contents

    S MART S ENSO R G AT EWAY Table of Contents GENERAL 2 INSTALLATION Prerequisites for Installation Recommended Location Gateway Configuration PoE Connection LAN/Ethernet Cable Connection WIFI Connection USB Mobile Dongle Connection Firewall Configuration 3 SCANNING BLUETOOTH DEVICES 4 TROUBLESHOOTING 2 019 -0 2 -08 2 /16...
  • Page 3: General

    S MART S ENSO R G AT EWAY General Smart Sensor Gateway is used to upload the Smart Sensor data automatically to the Smart Sensor Portal. Gateway needs to be configured for internet access before it can start reading the Smart Sensors. Following internet connections are supported: PoE (Power over Ethernet) network LAN/Ethernet network together with PoE injector WIFI network...
  • Page 4: Installation

    Gateway cannot operate in networks with VPN (Virtual Private Network) In case there is a firewall used, TCP and UDP ports 5246 and 5247 need to be opened for communication with abb.cassia.pro (13.126.172.231) Mobile network needs to have adequate signal strength. In most demanding locations an extension USB cable or external antenna might be needed for USB modem/dongle.
  • Page 5: Recommended Location

    S MART S ENSO R G AT EWAY Recommended Location Height: Recommended height for the Gateway is 3-30 meters from ground level. Lower levels are also acceptable but they might have weaker Bluetooth signal levels due to obstacles. Orientation: Gateway has the best reception to the direction where the Cassia logo is shown on its side.
  • Page 6 (AC). This needs to be selected as “AC Managed Router” (default). Tx Power: In some countries Tx power needs to be adjustable. Default value is 20. AC Address: Type here the access controller address abb.cassia.pro AC-Router Comm. Ports: Ports 5246, 5247 are used (default)
  • Page 7 S MART S ENSO R G AT EWAY Connection Priority is where a priority connection method is selected in case there are several in use. Select the priority according to connection in use: Wired for PoE and LAN connections Wireless for WIFI connection 3G/4G for mobile USB dongle connection Figure 4 Basic Page 2 019 -0 2 -08...
  • Page 8: Poe Connection

    S MART S ENSO R G AT EWAY PoE Connection If a PoE (Power Over Ethernet) network is available, the Gateway can be configured to use it without any additional power supply. Figure 5 PoE Network Configuration From the Gateway Basic Page select: Connection Priority: Wired IP Allocation: DHCP or Static (in case the IP allocation is given) Press Apply at the bottom of the screen.
  • Page 9: Lan/Ethernet Cable Connection

    S MART S ENSO R G AT EWAY LAN/Ethernet Cable Connection If a LAN/Ethernet network is available, the Gateway can be configured to use it. Additional PoE injector (power supply) is needed. Figure 6 LAN Network Configuration From the Gateway Basic Page select: Connection Priority: Wired IP Allocation: DHCP or Static (in case the IP allocation is given) Press Apply at the bottom of the screen.
  • Page 10: Wifi Connection

    S MART S ENSO R G AT EWAY WIFI Connection Gateway can be configured to use an existing WIFI network. Additional PoE injector (power supply) is needed. Figure 7 WIFI Network Configuration From the Gateway Basic Page select: Connection Priority: Wireless Enter the SSID (name) of the WIFI network Enter the WIFI network password Change the Wireless operation mode from Hotspot to Client...
  • Page 11: Usb Mobile Dongle Connection

    S MART S ENSO R G AT EWAY USB Mobile Dongle Connection Mobile network can be used with a specific USB dongle. Additional PoE injector (power supply), Huawei MS2131i-8 USB dongle and a SIM card are needed. Figure 8 Mobile Network Configuration Gateway works with Huawei MS2131i-8 USB dongle.
  • Page 12: Firewall Configuration

    In case there is a firewall in the network which the Gateway is using, specific ports need to be opened. Figure 9 Firewall Configuration Firewall needs to have both TCP and UDP port 5246, 5247 opened Firewall should allow communication between the Gateway and abb.cassia.pro (13.126.172.231) 2 019 -0 2 -08 1 2 /16...
  • Page 13: Scanning Bluetooth Devices

    S MART S ENSO R G AT EWAY Scanning Bluetooth Devices Correct Gateway placement can be checked by scanning the Bluetooth devices within the Gateway’s range. Gateway location or orientation needs to be changed if all desired Smart Sensors are not visible for the Gateway or if the Smart Sensor is showing weak signal level. To enable the scanning, the router mode needs to be changed.
  • Page 14 S MART S ENSO R G AT EWAY Debug Tool now starts to list all Bluetooth devices within its range. For all scanned devices the tool is showing the MAC address and RSSI value. Sometimes the name is not available, but it is listed if known.
  • Page 15: Troubleshooting

    During the first use it can take up to few hours to get the first readings to the Smart Sensor Portal Check from the Status Page if it shows the Online Time. If not, please check the internet connection. For more support, please contact Smart Sensor support: support.smartsensor@abb.com 2 019 -0 2 -08 1 5/ 16...
  • Page 16 S MART S ENSO R G AT EWAY 2 019 -0 2 -08 16 /16...