Siemens SCALANCE X005 Operating Instructions Manual

Siemens SCALANCE X005 Operating Instructions Manual

Simatic net industrial ethernet switches
Hide thumbs Also See for SCALANCE X005:

Advertisement

SCALANCE X005 / X005TS
SIMATIC NET
Industrial Ethernet switches
SCALANCE X005 / X005TS
Operating Instructions
07/2014
C79000-G8976-C344-01
___________________
Introduction
___________________
Network topologies
___________________
Description of the device
___________________
Mounting
___________________
Connecting up
Maintenance and
___________________
troubleshooting
___________________
Technical specifications
___________________
Approvals
___________________
Dimension drawings
1
2
3
4
5
6
7
8
9

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE X005

  • Page 1 ___________________ SCALANCE X005 / X005TS Introduction ___________________ Network topologies ___________________ Description of the device SIMATIC NET ___________________ Mounting Industrial Ethernet switches ___________________ SCALANCE X005 / X005TS Connecting up Maintenance and ___________________ troubleshooting Operating Instructions ___________________ Technical specifications ___________________ Approvals ___________________...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Notes on the e1/E1 approval of the SCALANCE X005TS ............32 Noise test of the SCALANCE X005TS ..................33 Overvoltage test of the SCALANCE X005TS ................33 Mechanical stability (in operation)....................33 Dimension drawings ..........................35 Index..............................37 SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 4 Table of contents SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 5: Introduction

    The "SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks" manual contains additional information on other SIMATIC NET products that you can operate along with the SCALANCE X005 and SCALANCE X005TS IE switches in an Industrial Ethernet network. You can order the manual "SIMATIC NET Industrial Twisted Pair and Fiber Optic Networks",...
  • Page 6 Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.
  • Page 7: On The Product

    Industrial Ethernet linear bus or star structures with switching functionality. The devices are designed for installation in a cabinet. Note It is not possible to use a SCALANCE X005 or SCALANCE X005TS in a redundant ring because they do not support redundancy. Note If devices are supplied over long 24 V power supply lines or networks, measures are necessary to prevent interference by strong electromagnetic pulses on the supply lines.
  • Page 8: Unpacking And Checking

    60 ℃ to 65 °C. SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 9: Network Topologies

    Switching technology allows extensive networks to be set up with numerous nodes and simplifies network expansion. Which topologies can be implemented? Using the SCALANCE X005 and SCALANCE X005TS IE switches, you can implement star topologies. Note Keep to the maximum permitted cable lengths of the devices you are using. You will find the permitted cable lengths in the section "Technical specifications (Page 29)".
  • Page 10 Network topologies SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 11: Description Of The Device

    Standby redundancy IRT capability Fast learning Passive listening Log table SNTP + SICLOCK Cut Through Table 3- 2 Overview of the connection options X005 X005TS TP (RJ-45) Fast Ethernet 10 / 100 Mbps SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 12: Product Characteristics

    Description of the device 3.2 Product characteristics Product characteristics Possible attachments The SCALANCE X005 and SCALANCE X005TS have five RJ-45 jacks for connection of end devices or other network segments. Figure 3-1 SCALANCE X005 Note The SCALANCE X005 shown above has the same construction as the SCALANCE X005TS.
  • Page 13: Tp Ports (Twisted Pair)

    3.3 TP ports (twisted pair) TP ports (twisted pair) RJ-45 connector pinout With SCALANCE X005 and SCALANCE X005TS, the twisted-pair ports are designed as RJ- 45 jacks with MDI-X pin assignment (Medium Dependent Interface Autocrossover) of a network component. Pin number...
  • Page 14 If the pair of receiving cables is connected incorrectly (RD+ and RD- interchanged), the polarity is adapted automatically. Note The SCALANCE X005 and SCALANCE X005TS IE switches are plug-and-play devices that require no settings during commissioning. MDI / MDI-X autocrossover function With the MPI/MDI-X autocrossover function, the send and receive contacts of an Ethernet port are assigned automatically.
  • Page 15: Leds

    The port LEDs indicate the status of the ports. LED color LED status Meaning Green TP link exists, no data reception at port Yellow TP link exists, data reception at port Yellow Flashing Test phase during power on SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 16 Description of the device 3.4 LEDs SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 17: Mounting

    Twisted Pair and Fiber Optic Networks". Note Provide suitable shade to protect the device against direct sunlight. This avoids unwanted warming of the device and prevents premature aging of the device and cabling. SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 18: Installation On A Din Rail

    3. Fit the connectors for the power supply. See also section "Power supply (Page 23)". 4. Insert the terminal block into the sockets on the device. Figure 4-1 Installation on a 35 mm DIN rail SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 19 3. Release the DIN rail catch on the bottom of the device using a screwdriver. 4. Pull the lower part of the device away from the DIN rail. Figure 4-2 Removal from a 35 mm DIN rail SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 20: Installation On A Standard Rail

    To remove the device from the S7-300 standard rail, follow the steps below: 1. Disconnect all connected cables. 2. Release the screw on the bottom of the standard rail. 3. Remove the device from the standard rail. SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 21: Wall Mounting

    3. Insert the terminal block into the sockets on the device. 4. Screw the device to the wall. Note The wall mounting must be capable of supporting at least four times the weight of the device. SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 22 Mounting 4.4 Wall mounting SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 23: Connecting Up

    The power supply is non-floating. The following figure shows the position of the power supply of the SCALANCE X005 or SCALANCE X005TS and the assignment of the terminal block.
  • Page 24: Grounding

    Fitting the IE FC RJ45 Plug 180 to the IE FC Standard Cable You will find the notes on installation in the instructions that ship with the IE FC RJ45 Plug 180. Figure 5-1 IE FC 45 Plug 180 SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 25 If there is not enough space to release the lock with your hand, you can also use a 2.5 mm screwdriver. You can then remove the IE FC RJ45 Plug 180 from the RJ-45 jack. SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 26 Connecting up 5.3 IE FC RJ-45 Plug 180 SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 27: Maintenance And Troubleshooting

    Maintenance and troubleshooting Fuses The SCALANCE X005 and SCALANCE X005TS IE switches have a resettable fuse / PTC. If the fuse triggers (all LEDs are off despite correctly applied power supply), the device should be disconnected from the power supply for approximately 30 minutes before turning it on again.
  • Page 28 Maintenance and troubleshooting SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 29: Technical Specifications

    Technical specifications Note Unless mentioned otherwise, the technical specifications in the following table relate to the SCALANCE X005 and SCALANCE X005TS. Table 7- 1 Technical specifications of the SCALANCE X005 and SCALANCE X005TS Technical specifications Order number SCALANCE X005 6GK5005-0BA00-1AA3...
  • Page 30 The number of connected SCALANCE X Industrial Ethernet Switches influences the frame propagation time. When a frame passes through the SCALANCE X005 or SCALANCE X005TS, it is delayed by the store and forward function of the switch: • with a 64 byte frame length by approx. 10 µs (at 100 Mbps) •...
  • Page 31: Approvals

    You can check which of the following approvals have been granted for your product by the markings on the type plate. Approvals_intro_X-000 The following approvals apply to the SCALANCE X005 and SCALANCE X005TS. EMC directive The devices meet the requirements of the EC Directive 2004/108/EC "Electromagnetic Compatibility".
  • Page 32: Note For Australia

    Underwriters Laboratories Inc. complying with ● UL 60950-1 (Information Technology Equipment) ● CSA C22.2 No. 60950-1-03 Report no. E115352 Notes on the e1/E1 approval of the SCALANCE X005TS Product name Product Order number SCALANCE X005TS 6GK5005-0BA00-1CA3 SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 33: Noise Test Of The Scalance X005Ts

    DIN EN 60068-2-27 shock 10 - 58.12 Hz: 0.075 mm 150 m/s , 11 ms duration 58.12 - 500 Hz: 10 m/s 6 shocks per axis 10 cycles X005 ● ● X005 TS ● ● SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 34 Approvals 8.7 Mechanical stability (in operation) SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 35: Dimension Drawings

    Dimension drawings Figure 9-1 Dimension drawing, rear of SCALANCE X005 or SCALANCE X005TS SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 36 Dimension drawings Figure 9-2 Dimension drawing, side view of SCALANCE X005 or SCALANCE X005TS SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 37: Index

    S7 standard rail, 24 Possible attachments Wall mounting, 24 SCALANCE X005, 12 SCALANCE X005TS, 12 Power LED, 15 Power supply, 23 IE FC RJ-45 Plug 180, 24 Pin assignment, 23 Installation, 24 Product characteristics, 11 SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...
  • Page 38 SIMATIC NET glossary, 6 Switching properties, 30 Technical specifications, 29 Connector, 29 Design, dimensions and weight, 30 Electrical data, 29 Order numbers, 29 Permitted ambient conditions, 29 Permitted cable lengths, 29 Switching properties, 30 SCALANCE X005 / X005TS Operating Instructions, 07/2014, C79000-G8976-C344-01...

This manual is also suitable for:

Scalance x005ts

Table of Contents