Ignition Transformer - DeWalt DXH50KTHC Instruction Manual

Kerosene forced-aid heater
Table of Contents

Advertisement

Available languages

Available languages

18AWG GRN
18AWG BLK
1
18AWG WHT
CORD SET
18AWG GRN
AC OUTLET
125KT,175KT,
210KT ONLY
18AWG ORG
18AWG ORG
MOTOR
18AWG PINK
18AWG PINK
WIRING DIAGRAMS
ON/OFF SWITCH
18AWG YELL
2
18AWG YELL
3
18AWG BLUE
75KT,125KT,175KT,210KT ONLY
H2
H1
FLAME CONTROL SCHEMATIC
(connections may not be in same
position on circuit board)
M1
M2
N
L
MOTOR CAPACITOR
HI-LIMIT
SWITCH
THERMOSTAT
18AWG PURPLE
18AWG PURPLE
17AWG BLK
I2
I1
ELECTR0DE
18AWG GRN
18AWG RED

IGNITION TRANSFORMER

18AWG RED
11
DXH50KTHC
DXH75KTHC
The parts lists and wiring diagram show
the heater as it was constructed. Do not
use a heater which is different from that
shown. Heater performance is effected
by air pressure setting. If there is any
uncertainty about the air pressure setting,
have it checked. A heater which is not
working right must be repaired, but only by
a trained, experienced service person.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxh135kthcDxh75kthcDxh175kthcDxh210kthc