Siemens AC-21 Brochure page 10

Switch disconnectors and fuses
Table of Contents

Advertisement

SENTRIC Switch Disconnectors
SENTRIC LD Main Control and EMERGENCY STOP Switches from 16 A to 125 A
Accessories
Selection and ordering data
For front mounting
3LD9 2.0-0B
3LD9 2.0-2B
3LD9 2.0-3B
3LD9 2.0-5B
7
For front and base mounting
3LD9 286-1A
3LD9 2.4-1A
3LD9 2.1-0A
3LD9 2.1–-2A
For base mounting and for distribution board mounting
3LD9 2.0-0C
3LD9 2.0-2C
7/10
Siemens LV 10 · 2004
DT
4th contact
(N conductor)
for front mounting
leading switch-on,
delayed switch-off
}
N or PE/ground terminal
continuous
Auxiliary switch
for mounting on left and/or right
delayed switch-off,
leading switch-on
}
1 NO + 1 NC
1 NO
A
1 NC
A
Auxiliary switch
for mounting on left and/or right
leading switch-on
with gold-plated contacts
for SIMATIC request
A
Labelling plate
A
English/German
Rotary operating mechanism
lockable in 0 position
with max. 3 padlocks
For four-hole mounting
black
A
red/yellow
A
For center-hole mounting
black
A
red/yellow
A
Labelling plate
A
English/German
Terminal cover as
additional touch protection
Can be snapped onto top and
bottom
1-pole (1 pack = 100 units)
A
3-pole (1 pack = 4 units)
4-pole (1 pack = 4 units)
A
4th contact
(N conductor)
for mounting on the rear
leading switch-on,
delayed switch-off
}
N or PE/ground terminal
continuous
Auxiliary switch
for mounting on the left
and/or right
delayed switch-on,
leading switch-off
}
1 NO + 1 NC
1 NO
A
1 NC
A
Labelling plate
A
English/German
3LD2 0
PS*
Weight
per PU
approx.
Order No.
kg
3LD9 200–2B
1 unit
0.030
3LD9 220–5B
1 unit
0.046
3LD9 220–3B
1 unit
0.029
3LD9 220–4B
1 unit
0.029
1 unit
0.029
3LD9 220–3B
3LD9 286–1A
1 unit
0.005
3LD9 224–1B
1 unit
0.072
3LD9 224–3B
1 unit
0.075
3LD9 224–1D
1 unit
0.080
3LD9 224–3D
1 unit
0.081
3LD9 286–1A
1 unit
0.005
3LD9 201–2A
1 unit
0.007
3LD9 201–1A
1 unit
0.007
3LD9 200–2C
1 unit
0.032
3LD9 220–5C
1 unit
0.046
3LD9 220–3C
1 unit
0.029
3LD9 220–4C
1 unit
0.030
3LD9 286–1A
1 unit
0.005
* This quantity or a multiple thereof can be ordered.
DT
3LD2 1 and
PS*
3LD2 2
Order No.
}
3LD9 220–0B
1 unit
}
3LD9 220–2B
1 unit
}
3LD9 220–5B
1 unit
A
3LD9 220–3B
1 unit
A
3LD9 220–4B
1 unit
A
1 unit
3LD9 220–3B
A
3LD9 286–1A
1 unit
A
3LD9 224–1B
1 unit
A
3LD9 224–3B
1 unit
A
3LD9 224–1D
1 unit
A
3LD9 224–3D
1 unit
A
3LD9 286–1A
1 unit
A
3LD9 221–2A
1 unit
A
3LD9 221–0A
1 unit
}
3LD9 220–0C
1 unit
}
3LD9 220–2C
1 unit
}
3LD9 220–5C
1 unit
A
3LD9 220–3C
1 unit
A
3LD9 220–4C
1 unit
A
3LD9 286–1A
1 unit
Weight
per PU
approx.
kg
0.039
0.036
0.046
0.029
0.029
0.029
0.005
0.072
0.075
0.080
0.081
0.005
0.004
0.007
0.039
0.037
0.046
0.029
0.030
0.005

Hide quick links:

Advertisement

Table of Contents
loading