Mitsubishi Electric MELSEC iQ-RJ71EN71 User Manual page 259

Ethernet
Hide thumbs Also See for MELSEC iQ-RJ71EN71:
Table of Contents

Advertisement

Item
Bit device
Points
Type
Start
End
Word device
Points
Type
Start
End
Communication time-out period (ms)
Communication retry count
Monitoring time at error (s)
Comment
*1 When the device type of the communication destination is an "SLMP-compatible device (QnA-compatible 3E frame)", the value is fixed
to 65535ms.
*2 When the device type of the communication destination is an "SLMP-compatible device (QnA-compatible 3E frame)", the value is fixed
to 0.
Communication destination setting
The following table lists the communication destination setting specified for the simple CPU communication.
Item
Device Type
UDP/TCP
IP Address
Description
Set the type, start number, and end number of the "Source" bit
device and the type and start number of the "Destination" bit
device. When these values are input, the number of points will
be displayed automatically.
Set the type, start number, and end number of the "Source"
word device and the type and start number of the "Destination"
word device. When these values are input, the number of points
will be displayed automatically.
Sets the time period until the retry is performed, the time period
until a communication error occurs, and the time period to wait a
response from the communication destination after an error
response from the communication destination.
Configure the setting so that (communication time-out period) 
(execution interval).
For details on the communication time-out period, refer to the
following.
Page 206 Communication Time-out Period/Communication
Retry Count/Monitoring Time At Error
Sets the number of communication retry to be performed within
the communication time-out period when the communication
destination returns an error response or does not respond.
For details on the communication retry count, refer to the
following.
Page 206 Communication Time-out Period/Communication
Retry Count/Monitoring Time At Error
Sets the communication time after a communication error
occurred.
For details on the monitoring time at error, refer to the following.
Page 206 Communication Time-out Period/Communication
Retry Count/Monitoring Time At Error
Sets a comment for the setting number, if required.
Description
Specify the device type of the communication destination.
Set the protocol used for the communication.
Enter the IP address of the communication destination.
Setting range
The setting range differs depending on
the communication destination.
(Page 198 Devices that can be
specified)
10 to 65535ms (in increments of
*1
1ms)
(Default: 1000ms)
*2
0 to 255 times
(Default: 3)
1 to 300s
(Default: 30s)
32 one-byte characters (16 double-
byte characters) maximum
(Default: Blank)
Setting range
• MELSEC iQ-R (built-in Ethernet)
• MELSEC-Q (built-in Ethernet)
• MELSEC-L (built-in Ethernet)
• MELSEC iQ-F (built-in Ethernet)
• MELSEC iQ-R (Ethernet module)
• MELSEC-Q (Ethernet module)
• MELSEC-L (Ethernet module)
• SLMP-compatible device (QnA-compatible 3E
frame)
• OMRON (CS/CJ series)
• KEYENCE (KV series)
• Panasonic (FP2SH series)
• Panasonic (FP7 series)
• YASKAWA MP3000 series
• YASKAWA MP2000 series
• Yokogawa FA-M3 series
• MODBUS/TCP-compatible device
(Default: Blank)
• UDP
• TCP
(Default: Blank)
0.0.0.1 to 223.255.255.254
(Default: Blank)
2 PARAMETER SETTINGS
2.3 Application Settings
2
257