Advertisement

1. SPECIFICATIONS ................................................................................................................................................. PMFY-3
2. EXTERNAL DIMENSIONS .................................................................................................................................... PMFY-4
3. CENTER OF GRAvITY ......................................................................................................................................... PMFY-5
4. ELECTRICAL WIRING DIAGRAMS ...................................................................................................................... PMFY-6
5. SOUND PRESSURE LEvELS .............................................................................................................................. PMFY-7
5-1.
Sound Pressure Levels ............................................................................................................................... PMFY-7
5-2.
NC Curves ................................................................................................................................................... PMFY-7
6. TEMPERATURE/AIRFLOW DISTRIBUTIONS ..................................................................................................... PMFY-8
6-1.
Temperature Distributions ........................................................................................................................... PMFY-8
6-2. Airflow Distributions ..................................................................................................................................... PMFY-8
7. OPTIONAL PARTS ................................................................................................................................................ PMFY-9
7-1.
External Heater Adapter CN24RELAY-KIT-CM3 ......................................................................................... PMFY-9
© 2012 Mitsubishi Electric US, Inc.
2012 PMFY-P-NBMU-ER5 (October 2012)
PMFY-1

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PMFY-P-NBMU-ER5

  • Page 1: Table Of Contents

    NC Curves ..............................PMFY-7 6. TEMPERATURE/AIRFLOW DISTRIBUTIONS ..................... PMFY-8 6-1. Temperature Distributions ........................... PMFY-8 6-2. Airflow Distributions ............................. PMFY-8 7. OPTIONAL PARTS ..............................PMFY-9 7-1. External Heater Adapter CN24RELAY-KIT-CM3 ..................PMFY-9 2012 PMFY-P-NBMU-ER5 (October 2012) PMFY-1 © 2012 Mitsubishi Electric US, Inc.
  • Page 2: Ceiling-Recessed Cassette (One-Way Airflow)

    17,000 20,000 27,000 30,000 34,000 40,000 54,000 60,000 80,000 108,000 PMFY-P-NBMU-ER5 * Nominal conditions *1, *2 are referred to in the Specification sheet. PMFY-P-NBMU-E IU - D - 2 PMFY-2 2012 PMFY-P-NBMU-ER5 (October 2012) © 2012 Mitsubishi Electric US, Inc.
  • Page 3: Specifications

    47degF D.B. / 43degF W.B. Outdoor: 95degF D.B. (35degC D.B.) lbs = kg / 0.4536 (8.3degC D.B. / 6.1degC W.B.) *Above specification data is Pipe length: 25 ft. (7.6 m) 25 ft. (7.6 m) subject to rounding variation. Level difference: 0 ft. (0 m) 0 ft. (0 m) *Due to continuing improvement, above specification may be subject to change without notice. 2012 PMFY-P-NBMU-ER5 (October 2012) PMFY-3 © 2012 Mitsubishi Electric US, Inc.
  • Page 4: External Dimensions

    2. ExtERNal diMENsiONs PMFY-P06,08,12,15NBMU-ER5 Drw. : IU-BH01C848 Unit : in(mm) PMFY-4 2012 PMFY-P-NBMU-ER5 (October 2012) © 2012 Mitsubishi Electric US, Inc.
  • Page 5: Center Of Gravity

    Model name PMFY-P06NBMU-ER5 165 [6-1/2] 390 [15-3/8] 130 [5-1/8] PMFY-P08NBMU-ER5 165 [6-1/2] 390 [15-3/8] 130 [5-1/8] PMFY-P12NBMU-ER5 165 [6-1/2] 390 [15-3/8] 130 [5-1/8] PMFY-P15NBMU-ER5 165 [6-1/2] 390 [15-3/8] 130 [5-1/8] 2012 PMFY-P-NBMU-ER5 (October 2012) PMFY-5 © 2012 Mitsubishi Electric US, Inc.
  • Page 6: Electrical Wiring Diagrams

    4. ElECtRiCal wiRiNg diagRaMs PMFY-P06,08,12,15NBMU-ER5 Drw. : IU-BH79C630 PMFY-6 2012 PMFY-P-NBMU-ER5 (October 2012) © 2012 Mitsubishi Electric US, Inc.
  • Page 7: Sound Pressure Levels

    10.0 10.0 10.0 Octave band center frequencies <Hz> Octave band center frequencies <Hz> Octave band center frequencies <Hz> Ref.:NC_PMFY-P06NBMU-E Ref.:NC_PMFY-P08,12NBMU-E Ref.:NC_PMFY-P15NBMU-E 2012 PMFY-P-NBMU-ER5 (October 2012) PMFY-7 © 2012 Mitsubishi Electric US, Inc.
  • Page 8: Temperature/Airflow Distributions

    PMFY-8 2012 PMFY-P-NBMU-ER5 (October 2012) © 2012 Mitsubishi Electric US, Inc.
  • Page 9: Optional Parts

    Control board 88H --------- Electromagnetic contactor CN24 Fan speed setting cable External output cable Item with resistance Quantity Shape Refer to the Installation Manual for wiring and installation details. 2012 PMFY-P-NBMU-ER5 (October 2012) PMFY-9 © 2012 Mitsubishi Electric US, Inc.
  • Page 10 PMFY-10 2012 PMFY-P-NBMU-ER5 (October 2012) © 2012 Mitsubishi Electric US, Inc.

This manual is also suitable for:

Pmfy-1

Table of Contents