Figure 3-5 Requirements for the vertical deviation angle of an RRU
(1) RRU
Installing an RRU on a Pole
Figure 3-6
Figure 3-6 Diameter of a pole
l The diameter of a pole for installing an RRU ranges from 60 mm (2.36 in.) to 114 mm (4.49
Issue ()
level on a pole. When the horizontal distance between the main and auxiliary poles on a
tower is equal to or greater than 810 mm (23.62 in.), the side-mounted mode is
recommended for installing RRUs on the auxiliary pole to meet the minimum clearance
requirements. Otherwise, the standard mode is recommended for installing RRUs on the
auxiliary pole.
(2) Installation support (pole, U-steel, angle steel, or wall)
shows the diameter of a pole for installing an RRU.
CAUTION
in.). The recommended diameter is 80 mm (3.15 in.).
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Information About the Installation
12