Digital Outputs - Siemens CPU 31 Series Technical Data Manual

Table of Contents

Advertisement

6.6.7

Digital outputs

Introduction
This chapter contains the specifications for the digital outputs of CPUs 31xC.
The table includes the following CPUs:
• under CPU 313C-2, the CPU 313C-2 DP and CPU 313C-2 PtP
• under CPU 314C-2, the CPU 314C-2 DP and CPU 314C-2 PtP
Fast digital outputs
Technological functions use fast digital outputs.
Technical data
Table 6-13
Technical data of digital outputs
Technical data
Module-specific data
Number of outputs
Of those are fast outputs
Cable length
Unshielded
Shielded
Voltage, currents, potentials
Rated load voltage L+
Polarity reversal protection
Total current of outputs (per group)
Horizontal assembly
Up to 40° C
up to 60 °C
Vertical assembly
Up to 40° C
Electrical isolation
Between channels and the backplane bus
Between the channels
In groups of
Permitted potential difference
Between different circuits
Insulation test voltage
CPU 31xC and CPU 31x, Technical Data
Manual, 01/2006 Edition, A5E00105475-06
CPU 312C
CPU 313C
CPU 312C
CPU 313C
6
16
2
4
Caution:
You cannot connect the high-speed outputs of your CPU in parallel.
Max. 600 m
Max. 1000 m
CPU 312C
CPU 313C
24 VDC
No
Max. 2,0 A
Max. 3,0 A
Max. 1,5 A
Max. 2,0 A
Max. 1,5 A
Max. 2,0 A
Yes
No
Yes
8
75 VDC / 60 VAC
500 VDC
Technical data of CPU 31xC
6.6 Technical data of the integrated I/O
CPU 313C-2
CPU 314C-2
CPU 313C-2
CPU 314C-2
16
16
4
4
CPU 313C-2
CPU 314C-2
Max. 3,0 A
Max. 3,0 A
Max. 2,0 A
Max. 2,0 A
Max. 2,0 A
Max. 2,0 A
Yes
Yes
8
8
6-47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents