Protection Class
Moisture
Ambient temperature
Transport and storage temperature
Long-term storage temperature
Installation position
Coating
Cable between actuator and electronic unit
Weight; approx.
Supply voltage
Current at electronic unit [A] (230 V AC)
External fuse
Kommunikation

10 Communication

10.1 Conventional communication

Analog input
Analog output
3 digital inputs*,
BE 1 ... BE 3
(DI 1 ... DI 3)
3 digital outputs*,
BA 1 ... BA 3
(DO 1 ... DO 3)
Digital communication
Default settings
Voltage output U
V
Transmitter (optional)
Individual settings
OI/PME/LME/EAN823/EBN853/EBN861-EN
IP 66
≤ 95 % average; condensation not permitted
-25 ... 55 °C (-15 ... 130 °F)
-25 ... 70 °C (-15 ... 160 °F)
-25 ... 40 °C (-15 ... 105 °F)
on vertical support, cable gland at the bottom
2-layer component epoxy (RAL 9005, black)
Optional 5 m (16 ft), 10 m (32 ft) or 20 m (65 ft) with plug for connection to the actuator; max.
cable length between actuator and electronic unit: 100 m (328 ft)
40 kg (88 lbs)
230 V AC (190 ... 260 V); 47.5 ... 63 Hz; 1Ph
RHD2500-10
RHD4000-10
RHD8000-12
RHD16000-30
RSD50-10
RSD100-10.0
Safety fuse 35 A (Lindner) + thermal circuit breaker 16 A (ETA)
Fuse and circuit breaker are part of shipment
0 / 4 ... 20 mA; internal load EAI823, EAN823, EBN853 300 Ω; internal load EBN861 250 Ω
0 / 4 ... 20 mA, electrically isolated, max. load 500 Ω
Digital 0:
-3 ... 5 V or open, electrically isolated
Digital 1:
12 ... 35 V, electrically isolated
Potential free relay contact,
max. 60 V, 150 mA
RS 232 for commissioning and service, with optional FSK / HART
Behavior in 0/100 % end position:
Setpoint function:
Setpoint input:
Function selection:
Actual output value:
Digital inputs:
Digital outputs:
Positioning time-out:
24 V, 15 mA, electrically isolated ; e.g., for scanning external contacts
Supply for 2-wire transmitter with activated process controller in Contrac
See data sheet 10/68-2.40 or upon request
Power Electronic Unit EBN861 (Contrac)
l
at 230V
max
.
5.3 A
10.0 A
8.0 A
12.5 A
6.4 A
12.5 A
Hold with rated torque / rated force
Linear, set point = position value
4 ... 20 mA
Positioner, parameter: Setpoint
4 ... 20 mA
BE 1 (DI 1) M/A selection;
BE 2 / BE 3 (DI 2 / DI 3) manual intervention +/-
BA 1 (DO 1) ready for operation;
BA 2/3 (DO 2/3) end position signal 0 / 100 %
Not activated for standard actuators
Always activated for Ex actuators
Communication
l
(230 V)
pos.
approx. 40 ... 50% of l
max
.
®
or PROFIBUS DP