Heater Specifications - DeWalt DXH125FAVHC Instruction Manual

Forced air propane construction heater
Table of Contents

Advertisement

Available languages

Available languages

Heater Specifications

Model
DXH60FAVHC
PROPANE ONLY
Gas Type
30,000-60,000 BTU/hr
Rating
(8.8-17.6 kW)
115 V, 60 HZ, 1 Ø, 0.68 A
Electrical Input
Min. operating voltage: 100V
Gas Supply Specifications
Max Pressure to
Bottle Pressure
Regulator
Min. Pressure to
5 psig (34.5 kPa)
Regulator
Pressure from
11 " W.C. (2.73 kPa)
Regulator
1.4 - 2.8 lbs/hr
Fuel Consumption
(0.64 - 1.29 kg/hr)
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing injury or loss of
life.
- Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
- An LP cylinder not connected for use shall not be stored in the vicinity of this or
any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Ǟ Do not try to light appliance.
Ǟ Extinguish any open flame.
Ǟ Shut off gas to appliance.
- Service must be performed by a qualified service agency.
WARNING: Fuels used in liquefied propane gas appliances, and the products of combustion of such fuel, can expose you to chemicals including benzene, which is known to the state
of california to cause cancer and cause birth defects or other reproductive harm, for more information go to www.P65Warnings.ca.gov
Operating Precautions
This is a propane, direct-fired, forced air heater. It's intended use is primarily
DXH125FAVHC
temporary heating of buildings under construction, alteration or repair.
Propane is heavier than air. If propane leaks from a connection or fitting, it sinks to the
PROPANE ONLY
floor, collecting there with the surrounding air, forming a potentially explosive mixture.
75,000-125,000
Obviously, propane leaks should be avoided, so set up the propane supply with
(21.9 - 36.6 kW)
utmost care. Leak check new connections or reconnections with a soap and water
solution applied to connection: look for bubbles, listen for hiss of escaping gas, feel
15 V, 60 HZ, 1 Ø, 0.68 A
for extreme cold, smell for rotten egg odor. Do not use if leaking! Follow all connection
Min. operating voltage: 100V
instructions herein. Also, ask your propane dealer for advice on the propane
application and supply installation and ask him to check it if there are any questions.
This heater was designed and certified for use as a construction heater in accordance
Bottle Pressure
with ANSI Standard Z83.7
you have any questions about your applications. Other standards govern the use of
5 psig (34.5 kPa)
fuel gases and heat producing products in specific applications. Your local authority
can advise you about these.
11 " W.C. (2.73 kPa)
Direct-Fired means that all of the combustion products enter the heated space. Even
3.5 - 5.8 lbs/hr
though this heater operates very close to 100 percent combustion efficiency, it still
(1.59 - 2.63 kg/hr)
produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic.
We can tolerate small amounts but not a lot. CO can build up in a heated space
and failure to provide adequate ventilation could result in death. The symptoms of
inadequate ventilation are:
• headache • dizziness • burning eyes and nose • nausea • dry mouth or sore throat
So, be sure to follow advice about ventilation in these operating instructions.
Forced Air means that a blower or fan pushes the air through the heater. Proper
combustion depends upon this air flow; therefore, the heater must not be revised,
modified or operated with parts removed or missing. Likewise, safety systems must
not be circumvented or modified in order to operate the heater.
When the heater is to be operated in the presence of other people the user is
responsible for properly acquainting those present with the safety precautions and
instructions, and of the hazards involved.
3
CGA 2.14. Check with your local fire safety authority if

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxh60favhc

Table of Contents