3.2.7

Load project into the CPU

Introduction
In the next section, you will download the "Color_Filling_Station" project to the CPU.
Note
Displaying all compatible devices
If the desired CPU is not displayed after you have made the settings in the "Extended
download to device" dialog, click the option "Show all compatible devices".
Procedure
1. Open the CPU shortcut menu and select "Download to device" > "Hardware and software
2. From the drop-down lists, select the PG/PC interface type, the interface and the
3. Select the CPU from the compatible devices in the subnet and click "Load".
4. Confirm the two "Assign IP address" dialogs with "Yes" and "OK".
5. In the "Load preview" dialog, select the alternative entry for all entries set to "No action" in
6. Click "Load".
7. Confirm the "Start all" option and click "Finish".
S7-1500
Getting Started, 05/2014, A5E03981761-AC
(only changes)".
connection with the subnet.
the drop-down list and confirm open options.
Software section
3.2 Creating the program
57