Commissioning
3.3 STARTER commissioning tool
3.3.2.2

Load project to target device.

You can use this function to load the actual project from the PG/PC into the Control Unit. A
consistency check is first made for the project. If inconsistencies are detected, corresponding
messages are output. You must resolve the inconsistencies before loading. If the data is
consistent, then it will be transferred into the work memory of the Control Unit. In order to
execute this function in the online mode, the following operator actions are alternatively
available:
1. Select the drive unit and call the menu "Project > Load to target system".
or
2. Select the drive unit and call the shortcut menu "Target device > Load to target device".
Or
3. Select the drive unit and call the menu "Target system > Load > Load CPU/drive unit to
target device...".
Or
4. If the drive unit has a gray background, click the symbol
target device...".
3.3.2.3

Create data records (offline) and copy

Drive and command data sets (DDS and CDS) can be added in the drive's configuration
screen. Click the appropriate buttons to do this. Before data sets are copied, all the wiring
needed for both data sets should be completed.
For more information about data sets, refer to Chapter "Basics of the drive system" in the
SINAMICS S120 Function Manual Drive Functions.
3.3.2.4

Retentively saving data

You can use this function to save volatile Control Unit data to the non-volatile memory
(memory card). After backing up, the data is also retained if the 24 V Control Unit supply has
been switched off. In order to execute this function in the online mode, the following operator
actions are alternatively available:
1. Select the drive unit and call the menu "Target system > Copy RAM to ROM".
Or
2. Select the drive unit and call the shortcut menu "Target device > Copy RAM to ROM".
Or
3. If the drive unit has a gray background, click the symbol
Or
4. If, after every download into the target device, data is also to be automatically transferred
into the non-volatile memory, call the menu "Tools > Settings...".
5. Click the "Download" tab and activate the option "After loading, copy RAM to ROM". Click
"OK" to confirm this setting.