With starter
Hide thumbs Also See for Sinamics s120:
Table of Contents

Advertisement

4. Click "Specify".
The "Know-how Protection for Drive Unit - Specify Password" dialog box opens.
Image 3-12
5. In the "New password" field, enter the password (1 to 30 characters). Pay attention to
upper- and lower-case.
6. Enter it again in the "Confirm password" field and click "OK" to confirm the entry.
The dialog box is closed and the password is shown in encrypted form in the "Activate
Know-how Protection for Drive Unit" dialog box.
7. If, despite active know-how protection, you permit diagnostic functions, activate the "Allow
diagnostic functions (trace and measuring functions)" option with a mouse click.
This allows the trace function, the measuring function and the function generator to be
used despite know-how protection.
8. The "Copy RAM to ROM" option is active by default and ensures that the know-how
protection is permanently stored in the Control Unit. If you want to use the know-how
protection temporarily, deactivate this option.
9. Click "OK" to confirm the settings you made.
Know-how protection is now activated. If larger data volumes are being encrypted, a
progress display informs that the encryption or the activation of the know-how protection
is still running.
The text "Know-how protected" then appears instead of the content in all protected
parameters of the expert list.
Note
A detailed description of the know-how protection functions is provided in Chapter "Basics of
the drive system" in the SINAMICS S120 Function Manual Drive Functions.
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
Set a password for the know-how protection.
Commissioning
3.3 STARTER commissioning tool
99