Commissioning
3.4 Creating a project in the STARTER commissioning tool
Add a single drive
1. Double-click in the project tree on "Insert single drive unit".
The following settings are pre-assigned:
– Device type: CU320-2 PN
– Version: 4.5 or higher
– Online access: IP
– Address: 169.254.11.22
2. If necessary, correct the settings, and confirm with "OK".
Note
Bus address
The PROFINET address of the Control Unit must not be set for initial commissioning.
When delivered, the TCP/IP address of the Control Unit is set to 169.254.11.22. The
address can be correspondingly changed to meet individual requirements.
Configure the drive unit
Once you have created the project, you have to configure the drive unit. Some examples are
provided in the following Chapters.
118
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5