Commissioning
3.12 Selection and configuration of encoders
Encoder type
Absolute
linear
HTL/TTL
Incremental
encoders
square wave
rotary
SSI encoder
Absolute
absolute
rotary
SSI encoder
Absolute
absolute HTL
rotary
Linear en-
Incremental
coder
linear
SIMAG H2
Incremental
rotary
The SMC40 can only be completely configured if an associated EnDat 2.2 encoder is connected. Without a connected
1)
encoder, it is not possible to integrate the SMC40 into the topology.
3.12.2

Configuring an encoder

You can configure the encoders using an input screen in the STARTER commissioning tool.
You have three configuration options:
174
Encoder code Encoder evaluation procedure
2151
16000 nm, 1 Vpp, A/B, EnDat,
resolution 100 nm
3001
1024 HTL A/B R
3002
1024 TTL A/B R
3003
2048 HTL A/B R
3005
1024 HTL A/B
3006
1024 TTL A/B
3007
2048 HTL A/B
3008
2048 TTL A/B
3009
1024 HTL A/B unipolar
3011
2048 HTL A/B unipolar
3020
2048 TTL A/B R, with Sense
3081
SSI, singleturn, 24 V
3082
SSI, multiturn 4096, 24 V
Not for motor control,
only as a direct measurement system
3090
4096, HTL, A/B, SSI, singleturn
3109
2000 nm, TTL, A/B R distance-coded
2002
2048, 1 Vpp, A/B R
2003
256, 1 Vpp, A/B R
2004
400, 1 Vpp, A/B R
2005
512, 1 Vpp, A/B R
2006
192, 1 Vpp, A/B R
2007
480, 1 Vpp, A/B R
2008
800, 1 Vpp, A/B R
STARTER Commissioning Manual
Commissioning Manual, (IH1), 07/2016, 6SL3097-4AF00-0BP5
Evaluation module
SMC20, SMI20,
SME25
SMC30
SMC30
SMC30
SMC20, SMI20,
SME20
SMC20, SMI20,
SME20

Advertisement

Table of Contents