Display
Self-supervision and
protection indicator LEDs
Programmable LEDs
Control Circuit Breaker (CB)
Escape / Cancel
Navigation
Enter / Select
Local / Remote
Help
Front communication port
7
6
Use navigation buttons for entering to submenus
Ready-LED steady: OK, Ready-LED flashing: Internal Relay Fault (IRF),
Start-LED steady: protection started, Start-LED flashing: protection function blocked,
Trip-LED: protection operated
Can be programmed for alarming and indication with latching and/or flashing features
Press open/close and confirm by pressing enter. Note: control has to be in Local mode.
Used for canceling actions and leaving setting mode without saving the values.
Returns back to menu.
Left = go back, Right = go further, Up = scroll up, Down = scroll down.
Are also used for changing setting values.
Entering to parameter setting mode and confirming new values
Changes the control between Local/Remote
View help menu
RJ-45 port can be used for connecting the IED to a PC
3
10
8
9

Advertisement

loading

Summary of Contents for ABB Relion 611 Series

  • Page 1 — Quick Start Guide Relion® 611 series Display Use navigation buttons for entering to submenus Self-supervision and Ready-LED steady: OK, Ready-LED flashing: Internal Relay Fault (IRF), protection indicator LEDs Start-LED steady: protection started, Start-LED flashing: protection function blocked, Trip-LED: protection operated Programmable LEDs Can be programmed for alarming and indication with latching and/or flashing features Control Circuit Breaker (CB)
  • Page 2 Q U I C K S TA R T G U I D E R E L I O N ® 6 1 1 S E R I E S — Using the local HMI Accessing main menu and changing parameters Clearing events, indications and programmable LEDs Press to navigate to the main menu from the measurements...
  • Page 3 Q U I C K S TA R T G U I D E R E L I O N ® 6 1 1 S E R I E S — Using the Web HMI Connect PC to the IED front communication port with After you have changed the start value parameter, click...
  • Page 4 With regard to purchase orders, illustrations contained therein. Any reproduction, disclosure to third the agreed particulars shall prevail. ABB does not accept any responsibility parties or utilization of its contents – in whole or in parts – is forbidden whatsoever for potential errors or possible lack of information in this without prior written consent of ABB.