Dial-in setup for PPP server
'Dial-up' and test the FP Web-Server:
Pin assignment of the RS232C null modem cable
Comment:
144
The dial-up, connect screen is displayed.
If the dial-up, connect screen is not displayed use: Start  Control
Panel  Network and Dial-up Connections  "Null modem with
COM1 and 19200bps to PPP server"
1. Enter the name and password as defined in the FP Web-Server
configuration. Click [Connect]
The 'dial-up' process can take a few seconds. Upon a successful
connection an icon is displayed in the system status bar.
To disconnect later, click on this icon and select 'Disconnect'.
2. Use a standard Internet browser that is set up as described under
Internet Browser to Test the FP Web-Server (see p. 37)
3. In the location field the IP address of the PPP server can be entered,
e.g. http://192.168.206.4 (see FP Web-Server settings under PPP
server (see p. 130))
The page "MAIN.HTM" as setup with the Configurator should be
displayed.
The computer's COM port is directly connected to the FP Web-Server's
9-pin port via a null modem cable.
Use a standard null modem adapter having 9-pin, female, RS232C
connectors on both sides. The minimum wiring should be as follows: 2-3 ;
3-2 ; 5-5. (This is the minimum number of wires needed.) The minimum
wiring connects the GND and the data lines only. A 25-pin connection
should be as follows:
The bridges 4-5 and 6-20 on each side are not absolutely necessary. They
are only essential for questions of compatibility.