General information and networking
1.3 Connecting
USB sticks that deviate from these requirements have not been tested can may not be
recognized by the NCU.
PROFIBUS DP / MPI interface
Connector type:
Max. data transmission rate:
Max. cable length:
Table 1-7
PROFIBUS DP interface
Connector type:
Max. data transmission rate:
Max. cable length:
24
Assignment of the PROFIBUS DP / MPI interface
Connector
Pin
1,2
3
4
5
6
7
8
9
Shield
9-pin sub-D socket
12 Mbit/s
100 m
Name
Type
Remark
N.C.
-
Not connected
LTG_B
B
Signal line B of MPI module
RTS_AS
I
Control signal for receive data current. Signal 1
active if directly connected control is sending.
M5EXT
V
Return line (GND) of 5 V supply. Current load
from a load of 90 mA max. connected between
P5EXT and M5EXT.
P5EXT
V
5 V supply (current load see M5EXT)
N.C.
-
Not connected
LTG_A
B
Signal line A of MPI module
RTS_PG
O
RTS signal of MPI module; signal is "1", when
PG is sending
-
On connector housing
9-pin sub-D socket
12 Mbit/s
100 m
Operator panel front: OP 012