Error Message - Sony MP-F17W Service Manual

Micro floppydisk drive
Table of Contents

Advertisement

3-.... 3 Buor
Me •• ale
ERROR MESSAGB
Record not found
CRC error
ID ADM missing
Write protec terror
Drive not connected
CONSD>BRABLB CAUSB
1.
Stepping
motor
circuit
or
stepping motor itself is out
of order.
2. Read circuit is out of order.
1.
Off track, chucking trouble,
wrong head compliance.
1.
No
write
function.
(write
circuit is out of order, no
formatting)
2.
Off
track,
wrong
head
compliance, chucking trouble,
or disk.
1.
Condition
is
set
to
write
protect.
1. Disk is not inserted, or the
insertion is not detected.
2. DC power is not supplied, or
a drive is not selected.
-34-
COUNTBRMEASURB
(CONFlRMAnONI AD JUSl"METNTI
Confirm the function of stepping motor
circuit or stepping motor itself.
Confirm the read circuit.
check RF output)
(at first
Confirm
head
compliance
(Refer
to
5-2),
chucking
mechanism
or
radial
alignment and TRKOO sensor (Refer to
5-1).
Confirm the waveform of RF output.
Confirm
the
radial
alignm ent
and
TRKOO sensor (Refer
to
5-1), head
compliance (Refer to 5-2), or chucking
mechanism.
Confirm Media, write protec t circuit
or write protect mechanism.
Confirm disk detec t circuit.
Confirm
DC
power
supplier,
drive
select switch position and drive select
circuit.

Hide quick links: