5.5
The Blinking LED Procedure
5.5.1
Introduction
The software is capable of identifying different kinds of errors.
Because it is possible that more than one error can occur over
time, an error buffer is available, which is capable of storing the
last five errors that occurred. This is useful if the OSD is not
working properly.
Errors can also be displayed by the blinking LED procedure.
The method is to repeatedly let the front LED pulse with as
many pulses as the error code number, followed by a period of
1.5 seconds in which the LED is "off". Then this sequence is
repeated.
Example (1): error code 4 will result in four times the sequence
LED "on" for 0.25 seconds / LED "off" for 0.25 seconds. After
this sequence, the LED will be "off" for 1.5 seconds. Any RC5
command terminates the sequence. Error code LED blinking is
in red colour.
Example (2): the content of the error buffer is "12 9 6 0 0"
After entering SDM, the following occurs:
1 long blink of 5 seconds to start the sequence,
12 short blinks followed by a pause of 1.5 seconds,
9 short blinks followed by a pause of 1.5 seconds,
6 short blinks followed by a pause of 1.5 seconds,
1 long blink of 1.5 seconds to finish the sequence,
The sequence starts again with 12 short blinks.
5.5.2
Displaying the Entire Error Buffer
Additionally, the entire error buffer is displayed when Service
Mode "SDM" is entered. In case the TV set is in protection or
Stand-by: The blinking LED procedure sequence (as in SDM-
mode in normal operation) must be triggered by the following
RC sequence: "MUTE" "062500" "OK".
In order to avoid confusion with RC5 signal reception blinking,
this blinking procedure is terminated when a RC5 command is
received.
To erase the error buffer, the RC command "MUTE" "062599
"OK" can be used.
5.6
TV Main Software Upgrade
For instructions on how to upgrade the TV Main software, refer
to ComPair.
5.7
Fault Finding and Repair Tips
Notes:
It is assumed that the components are mounted correctly
with correct values and no bad solder joints.
Before any fault finding actions, check if the correct options
are set.
5.7.1
NVM Editor
In some cases, it can be convenient if one directly can change
the NVM contents. This can be done with the "NVM Editor" in
SAM mode. With this option, single bytes can be changed.
Caution:
Do not change the NVM settings without
understanding the function of each setting, because
incorrect NVM settings may seriously hamper the
correct functioning of the TV set!
Always write down the existing NVM settings, before
changing the settings. This will enable you to return to the
original settings, if the new settings turn out to be incorrect.
Service Modes, Error Codes, and Fault Finding
LC7.1A LA
Table 5-5 NVM editor overview
Hex
.ADR
0x000A
.VAL
0x0000
.Store
Store?
5.7.2
Load Default NVM Values
It is possible to download default values automatically into the
NVM in case a blank NVM is placed or when the NVM first 20
address contents are "FF". After the default values are
downloaded, it is possible to start-up and to start aligning the
TV set. To initiate a forced default download the following
action has to be performed:
1. Switch "off" the TV set with the mains cord disconnected
from the wall outlet (it does not matter if this is from
"Standby" or "off" situation).
2. Short-circuit the SDM jumpers on the SSB (keep short
circuited).
3. Press "P+" or "CH+" on the local keyboard (and keep it
pressed).
4. Reconnect the mains supply to the wall outlet.
5. Release the "P+" or "CH+" when the set is "on" or blue LED
is blinking.
When the downloading has completed successfully, the set
should be into Standby, i.e. red LED on.
Alternative method (1):
1. Go to SAM.
2. Select NVM Editor.
3. Select ADR (address) to 1 (dec).
4. Change the VAL (value) to 170 (dec).
5. Store the value.
6. Do a hard reset to make sure new default values took
place.
Alternative method (2):
It is also possible to upload the default values to the NVM with
ComPair in case the SW is changed, the NVM is replaced with
a new (empty) one, or when the NVM content is corrupted.
After replacing an EEPROM (or with a defective/no EEPROM),
default settings should be used to enable the set to start-up and
allow the Service Default Mode and Service Alignment Mode to
be accessed.
5.7.3
Replacing the SSB flash IC
When you have to replace the SSB flash IC (item 7310), refer
to the Spare Parts list for the correct order number. You will
then receive a pre-programmed flash IC which contains the
boot-loader firmware. Without this firmware, you cannot
program the TV with ComPair. Therefore you must order the
pre-programmed flash IC, which you will receive when using
the order number which is listed in the Spare Parts list.
5.7.4
Start-up/Shut-down Flowcharts
Important note for DVB sets:
When you put a DVB set into Stand-by mode with an RC,
the set will go to "Semi Stand-by" mode for 5 minutes. This,
to facilitate "Off the Air download" (OAD). If there is no
activity within these 5 minutes, the set will switch to Stand-
by mode. In "Semi Stand-by" mode, the LCD backlight and
Audio Amplifier are turned "off" but other circuits still work
as normal. The customer might think the set is in Stand-by.
However, in real Stand-by mode, only the uP and the NVM
are alive and all other circuits are switched "off".
If you press the mains switch at the local key board in a
DVB set, the set will switch to Stand-by mode.
5.
EN 25
Dec
Description
10
Existing value
0
New value

Advertisement