Mitsubishi Electric M80 Series Maintenance Manual page 50

Hide thumbs Also See for M80 Series:
Table of Contents

Advertisement

M800/M80/E80 Series Maintenance Manual
1 System Basic Configuration
FCU8-DX731/DX750/FCU8-DX760/FCU8-DX761 (M800S/M80/E80)
[LED]
FCU8-DX731
(1)
(2)
FCU8-DX760
(10)
(11)
(1)
(2)
No.
Name
(1)
FUSE
Fuse status
(2)
DOCOM
Energization status of DC24V input
(DOCOM) of CG32/CG36/CJ38/CJ40
connector
(3)
12VON
12V power supply circuit status
(4)
5VIN
5V power supply circuit status
(5)
3VIN
3.3V power supply circuit status
(6)
ALM1
RIO communication error
(7)
ALM2
RIO communication error
(8)
ALM3
RIO communication error
(6)
(3)
(4)
(5)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Function
Color
Green
Green
Green
Green
Green
Red
Red
Red
23
FCU8-DX750
(1)
(2)
FCU8-DX761
(1)
(2)
State
Supplement
Normal At fault
Lit
Not lit
Not lit when a fuse has been
blown out.
Lit
Not lit
Lit when a current is applied.
Lit
Not lit
Lit when the circuit is normally
operated.
Lit
Not lit
Lit when the circuit is normally
operated.
Lit
Not lit
Lit when the circuit is normally
operated.
Not lit
Lit
Lit when RIO communication
error has occurred.
Not lit
Lit
Lit when RIO communication
error has occurred.
Not lit
Lit
Lit when RIO communication
error has occurred.
(3)
(4)
(5)
(6)
(7)
(8)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
IB-1501273-F