Mitsubishi Electric A800 Plus Instruction Manual page 12

Separated converter type, roll to roll function
Hide thumbs Also See for A800 Plus:
Table of Contents

Advertisement

Ethernet model
(b)
(a)
(c)
(d)
(e)
(f)
Symbol
Name
(a)
Plug-in option connector 1
(b)
Plug-in option connector 3
(c)
Plug-in option connector 2
Voltage/current input switch
(d)
(SW2)
Ethernet communication
(e)
connector
(f)
Control circuit terminal block
(g)
PU connector
(h)
USB A connector
(i)
USB mini B connector
(j)
Upper front cover
(k)
Power lamp
(l)
Alarm lamp
(m)
Charge lamp
(n)
Operation panel (FR-DU08)
(o)
Lower front cover
(p)
Main circuit terminal block
(q)
Cooling fan
Switches for manufacturer
(r)
setting (SW3 and SW4)
∗1
Refer to the FR-A800 Instruction Manual (Detailed)
(g)
(i)
(r)
(j)
(k)
(l)
(n)
(m)
(o)
Connects a plug-in option or a communication option.
The connector 2 cannot be used because the Ethernet board is installed in the initial
status. The Ethernet board must be removed to install a plug-in option to the
connector 2. (However, Ethernet communication is disabled in that case.)
Selects between voltage and current for the terminal 2 and 4 inputs.
Connect the Ethernet dedicated cable for connection to the network.
Connects cables for the control circuit.
Connects the operation panel or the parameter unit. This connector also enables the
RS-485 communication.
Connects a USB memory device.
Connects a personal computer and enables communication with FR Configurator2.
Remove this cover for the installation of the product, installation of a plug-in
(communication) option, RS-485 terminal wiring, switching of the voltage/current input
switch, etc.
Stays ON while the power is supplied to the control circuit (R1/L11, S1/L21).
Turns ON when the protective function of the inverter is activated.
Stays ON while the power is supplied to the main circuit.
Operates and monitors the inverter.
Remove this cover for wiring.
Connects cables for the main circuit.
Cools the inverter.
Do not change the initial setting (OFF
Inverter component names
Description
OFF
).
ON
INTRODUCTION
(q)
(p)
Refer to
page
Instruction
Manual of
the option
59
1
∗1
59
41
56
57
57
18
37
37
37
∗1
18
36
102
11

Advertisement

Table of Contents
loading

Table of Contents