■Setting the RJ71EIP91 (target)
1.
Create a new project in the "Configuration Manager" window.
Right-click "EtherNet/IP Network" in the EtherNet/IP setting.
2.
Set the IP address of the RJ71EIP91 (target).
3.
Select the target in "Device Library" to add it to the network configuration setting.
Select the "Target(Class1 Tag)" in "Device Library".
4.
Configure the Class 1 tag communication settings for the RJ71EIP91 (target).
5.
Switch the engineering tool to the online state.
[File]
[Go Online]
7 COMMUNICATION EXAMPLE
38
7.1 Communication Example between RJ71EIP91 and EtherNet/IP Device
[Configuration Manager]
[Library]
[Insert in Configuration]
[New] button