Control From the PVE-500

Control using PVE-500 control signals
Downstream key control using GPI signals
Control From Editing
Control Units
You can combine the DFS-700/700P with the PVE-500 Editing Control
Unit to carry out A/B roll editing using two players and one recorder.
The PVE-500 controls the DFS-700/700P using PVE-500 control signals
and GPI signals.
Note
For details of preread editing, see the section "Preread Editing" (page 5-
14).
You can control the following DFS-700/700P functions using 9-pin serial
control signals from the PVE-500. Input these signals to the EDITOR
connector on the rear panel of the DFS-700/700P.
• Selecting the background image (FROM source) and foreground image
(TO source)
• Setting the transition duration
• Executing auto transitions
• Automatic snapshot (when you save editing data on the PVE-500, DFS-
700/700P snapshots are saved and recalled automatically.)
For more information about controlling these functions, refer to the PVE-500
Operating Instructions.
You can use GPI pulse signals from the PVE-500 to turn the DFS-700/
700P downstream key function on or off on the falling edge of a pulse.
Input the GPI signals to the T2 connector on the DFS-700/700P.
For details of GPI signal timing, see page 5-13.