Page 3
Read the precautions in this manual This appliance is filled with R32. carefully before operating the unit. Service indicator; Read technical Read the operator's manual manual The installation and service of this product shall be carried out by professional personnel, who have been trainedand certified by national training organizations that areaccredited to teach the relevant national competency standards that may be set in legislation.
Page 4
•A brazed, welded, or mechanical connection shall be made before opening the valves to permit refrigerant to flow between the refrigerating system parts. A vacuum valve shall be provided to evacuate the interconnecting pipe and/or any uncharged refrigerating system part. •The maximum working pressure is 4.3 MPa.
Page 5
The products are fulfilled with the requirements in the directive 2011/65/EU of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment(EU RoHS Directive) GWP:675 In accordance with the directive 2012/19/EU of the European f the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Page 6
The specification of power cable is HO5RN-F3G 4.0mm . The specification of cable between indoor unit to outdoor unit is HO5RN-F4G 2.5mm...
Page 7
Cautions - The installation of pipe-work shall be kept to a minimum. - Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than Amin(2m2). - Compliance with national gas regulations shall be observed. - Mechanical connections shall be accessible for maintenance purposes.
Page 8
Cautions Checks to electrical devices - Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.
Page 9
Cautions - Become familiar with the equipment and its operation. - Isolate system electrically. - Before attempting the procedure, ensure that: • mechanical handling equipment is available, if required, for handling refrigerant cylinders; • all personal protective equipment is available and being used correctly; •...
Remote Controller Operation Manual External View of Remote Controller Functional description 1. Power-up and Show All: After inserting the batteries the display will show all symbols for 3 seconds. The remote will then enter clock set mode. Use “+/-“ to adjust the clock. Press “Confirm” when done. If no action is taken within 10 seconds then the remote will exit set mode.
Page 14
Remote Controller Operation Manual The TURBO function is used for fast heating or cooling. 8. Vertical SWING Buttion Press TURBO button, the remote control will display the TURBO and Air Flow Direction Adjustment switch the fan to SUPER high. Press TURBO button again to cancel Press the SWING UP/DOWN button to choose the position of the function.