Provisioning Clear - NEC IPASOLINK 400 Installation And Provisioning

Hide thumbs Also See for IPASOLINK 400:
Table of Contents

Advertisement

40
Note: if suitable basic configuration files are first copied to each IDU, following the Quick Installation Guide
(Appendix D) is sufficient. The basic configuration files should contain all the default settings for the
operator. Then only those settings that vary from each NE to NE need to be changed during installation.

PROVISIONING CLEAR

If the IDU is not at the factory settings, it may be useful to return all Provisioning Settings to factory settings
using Equipment Utility -> Shipment -> Shipment.
This operation disables all modems and other cards and removes all settings under Provisioning. Note: e.g
Network Management Configuration and Security Management settings (such as NMS port adresses and
SNMP, NMS and NTP server addresses etc.) remain unchanged.
Before the Provisioning Clear it is necessary to set the MAINT status on. Select "Provisioning Clear". The
IDU will be reset, and it is necessary to wait a few minutes for the reset to complete. The operation is
finished when the MAINT led stops blinking and LCT port is again operable.
Note. Possible only locally using the LCT port. Not possible remotely using the NMS port.
MODULE SETUP
It is normally not useful to use the "Easy Setup Wizard" because the detailed settings need to be changed
anyway.
Equipment Setup -> Equipment Configuration -> Setup
Changes are made using the Setup button. The setting window shows the Current Setting and on the right
the New Setting is used to input new values. Continue by clicking Next > and OK.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents