86
Turn off the target IDU. Wait for at least 10 seconds. Insert the USB stick with config folder and the CFG-
files into the USB port of the IDU. Turn the PROTECT switch UP. Now reconnect DC-power to the IDU. Wait
for about 2 minutes until the MAINT led stops flashing but remains ON. Now turn the PROTECT switch back
DOWN (normal position). After one minute the MAINT led will start flashing again (rebooting). Wait one
more minute until the MAINT led stops flashing and remains OFF. Remove the USB stick now. The IDU
should now operate using the settings copied from the USB folder.
COPYING SETTINGS USING THE BROWSER
Equipment Utility -> Export (NE -> Storage) Utility
Figure 79. Copying (export) settings to the local PC
Select e.g. Equipment Config Data and press Execute. Browser window opens, select Save File and select a
suitable folder and save the file.
If the IDU USB port has a USB stick inserted, it is possible to select Export to USB Memory. Press Execute
and wait for window "Complete" and press OK.