Air/Oil/ Water Flow; Compressed Air Flow; Oil Flow; Cooling Air Flow - Hitachi NEXT Series Instruction Manual

Oil-free rotary screw air compressor
Hide thumbs Also See for NEXT Series:
Table of Contents

Advertisement

⑻ Air intake filter
The air intake filter is a dry type for easy cleaning or
replacement.
⑼ Fan  
Air-Cooled
The low noise cooling fan cools the cooler, exhausts
the hot air within the enclosure, and exhausts the
inter nal compressed air that is released to
atmosphere during the unloading (purging) process.
Water-Cooled
The small cooling fan cools the inside of the
package, and exhausts the internal compressed air
that is
released to atmosphere during the
unloading (purging) process.
※ The indication in the (
⑽ Control panel
The control panel employs a printed circuit board
on which a microprocessor is mounted to achieve
easy operation. The air compressor can be operated
remotely.
⑾ Enclosure
The enclosures are attached with the sound
absorbing materials. The front and left enclosure
panel includes a door that enables easy maintenance.
8. STANDARD COMPONENTS AND SUBSYSTEMS [Air/Oil/Water Flow]
) is for Vtype.

8.2 Air/Oil/ Water Flow

Compressed Air Flow

Intake air is compressed and heated by the 1st stage
airend and pressure builds up to approximately 29 psi
(0.20MPa) The heated air is cooled down by the
intercooler and then further compressed and heated by
the 2nd stage airend as pressure builds up to the rated
pressure level of the air compressor. The reheated air
flows through the check valve to the aftercooler, where
the compressed air is cooled down and then discharged
to the plant compressed air piping.

Oil Flow

The oil sump is located in the bottom of the gear case.
Oil is sucked through an oil strainer (oil strainer has a
100-mesh filter screen) by the oil pump and is
hydraulically fed to the oil cooler where it is cooled.
During the cooling process, oil flows through the high-
precision oil filter and is then injected onto the bearings
of the 1st and 2nd stage airends as well as the stepup
gears. Oil returns to the oil sump, where it continues
to circulate through the system.
Air-Cooled

Cooling Air Flow

The cooling fan removes the heat from the air-cooled,
oil cooler, intercooler, aftercooler and Hi-precooler, and
this heat exchanged air is exhausted through the air
exhaust grill on the top of the enclosure.
Water-Cooled
Cooling Water Flow
Incoming water cools the intercooler, the water jackets
of the airends, the aftercooler and the oil cooler. Refer
to "Cooling Water Flow Diagram" for the detail of
cooling water flow (
see the flow diagram from next
page).
61