Siemens SIMATIC NET PS598-1 Compact Operating Instructions

For scalance xr500
Hide thumbs Also See for SIMATIC NET PS598-1:

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET PS598-1

  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Table of contents Introduction ....................3 Safety notes ....................3 Description ....................4 Product characteristics ................. 4 Unpacking and checking ..............5 Mounting ......................6 19" rack mounting of the PS598-1 ............6 Mounting the PS598-1 on the rear panel of an XR500 ......8 Connection ....................
  • Page 5: Introduction

    Introduction Purpose of the compact operating instructions Based on the compact operating instructions, you will be able to install and connect up the PS598-1 correctly. Validity of these compact operating instructions These compact operating instructions apply to the product PS598-1 as of product version 1.
  • Page 6: Description

    Description Product characteristics Connectors Type Power Input voltage Output voltage PS598-1 300 W 100 to 240 VAC 24 VDC Note Two connectors for the 24 VDC output voltage The PS598-1 has two connectors with the output voltage 24 VDC. Note that you can only use one connector on the front or the connector on the rear of the PS598-1.
  • Page 7: Unpacking And Checking

    1. Make sure that the package is complete. 2. Check all the parts for transport damage. If the consignment is incomplete or if there is damage to the exterior, contact your supplier or your local Siemens office. Power supply unit PS598-1 for SCALANCE XR500 A5E03275848-04, 05/2013...
  • Page 8: Mounting

    Mounting 19" rack mounting of the PS598-1 Power supply unit for 19" rack installation The PS598-1 was developed specifically for use with devices of the XR500 product group. This power supply unit can be mounted directly above or below a SCALANCE XR500 since the ventilation grilles are on the sides of both the basic device and the power supply unit.
  • Page 9 Mounting Procedure Follow the steps below to install the PS598-1 in a 19" rack: 1. Secure the two mounting brackets with four screws each (M3 x 6 supplied with the product) to the side panels of the power supply unit. The maximum tightening torque for these screws is 0.5 Nm.
  • Page 10: Mounting The Ps598-1 On The Rear Panel Of An Xr500

    Mounting Mounting the PS598-1 on the rear panel of an XR500 NOTICE Damage to the device due to inadequate cooling If the ventilation grilles are fully or partly covered or the air filters are contaminated, the temperature inside the housing can rise and exceed the maximum permitted temperature and damage the device.
  • Page 11 Mounting Procedure Figure 4-1 Rear panel mounting of the SCALANCE XR552-12M. SCALANCE XR528-6M is used analogously. Power supply unit PS598-1 for SCALANCE XR500 A5E03275848-04, 05/2013...
  • Page 12 Mounting On the rear panel of a SCALANCE XR500, there are sockets for the direct connection of a maximum of two PS598-1 power supply units. On the rear of the PS598-1 there is a corresponding plug. Follow the steps below to install the PS598-1 on the rear panel of a SCALANCE XR500: 1.
  • Page 13: Connection

    Connection Connecting devices with 100 to 240 VAC power supply Switches for the input voltage ① ③ The socket X1 (position ) and the switch S1 Power (position ) for the input voltage are located on the right-hand side of the front panel of the housing: NOTICE Connect and disconnect the power supply unit only when it is not energized! The PS598-1 is not capable of hot plugging.
  • Page 14 Connection NOTICE Reliable grounding Reliable grounding of the devices mounted in the rack must be guaranteed. This applies, in particular, to power supply cables that are not connected directly to the power supply circuit. With the PS598-1, the IEC power connector (IEC 60320-1) provides the connection to protective earth.
  • Page 15 Connection Pin assignment of the X3 plug on the rear Connector X3 is located on the back of the PS598-1. Connector X3 is intended only to connect the PS598-1 directly to an XR500. Contact Assignment +24 VDC Ground Power supply unit PS598-1 for SCALANCE XR500 A5E03275848-04, 05/2013...
  • Page 16 Connection One PS598-1 per device, no redundancy Figure 5-1 Connecting a power supply unit to a SCALANCE XR552-12M. SCALANCE XR528-6M is used analogously. Connect the SCALANCE XR500 and the PS598-1 with one cable for 24 VDC and a cable for ground. As an alternative, you can also mount the PS598-1 on the back of the SCALANCE XR500 and secure it with screws.
  • Page 17 Connection Three PS598-1 units for two devices - 2-out-of-3 redundancy Figure 5-3 Connecting three power supply units to a SCALANCE XR552-12M. SCALANCE XR528-6M is used analogously. Connect each SCALANCE XR500 to its own PS598-1. In addition to this, connect both SCALANCE XR500 devices to the third PS598-1. Both SCALANCE XR500 devices can now continue to operate after the failure of one PS598-1.
  • Page 18: Led Display

    Connection In areas subject to the NEC or CEC: WARNING Safety notice for connectors with LAN (Local Area Network) marking A LAN or LAN segment, with all its associated interconnected equipment, shall be entirely contained within a single low-voltage power distribution and within a single building.
  • Page 19: Upkeep And Maintenance

    Upkeep and maintenance The PS598-1 has a service panel, behind which there is a removable air filter. The air filter can be replaced during operation. Procedure 1. Open the service panel. 2. Take the air filter out of the device. 3.
  • Page 20: Technical Data

    Technical data Device variants The following technical specifications apply to the following device: ● PS598-1 Connectors Interface Execution ● 4-pin terminal block for 2 x 24 VDC on the front of the device. Power ● Plug on the rear of the housing for direct connection to a SCALANCE XR500.
  • Page 21: Dimension Drawings

    Dimension drawings Environmental conditions Property Value Transportation/storage temperature -40 °C to +85 °C Operating temperature 0 °C to +60 °C Maximum relative humidity < 95 % no condensation in operation at 25 °C ● 2000 m at max. 56 °C Operating altitude above sea level depending on ambient temperature ●...
  • Page 22: Approvals

    Approvals The SIMATIC NET products described in these Operating Instructions have the approvals listed below. Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate.
  • Page 23 The current descriptions of the currently available products can always be found on the Internet under the specified entry IDs/Internet pages: – SIMATIC NET Industrial Ethernet Network manual ID = 27069465 (http://support.automation.siemens.com/WW/view/en/27069465) – EMC Installation Guideline, Planning Guide ID = 28518276 (http://support.automation.siemens.com/WW/view/en/28518276) –...
  • Page 24: Mechanical Stability (In Operation)

    *) Note: When rack mounted with four securing points Trademarks All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.