Environmental Type Tests - Siemens RUGGEDCOM RX1510 Installation Manual

Simatic net industrial ethernet switches
Hide thumbs Also See for RUGGEDCOM RX1510:
Table of Contents

Advertisement

Certification
6.2 EMC and Environmental Type Tests

Environmental Type Tests

52
Description
ESD
Test
IEC 60068-2-1
Cold Temperature
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
IEC 61373
IEC 60255-21-3
MIL-STD-810G
Enclosure Contact
Enclosure Air
Description
Test Ad
Dry Heat
Test Bd
Humidity (Damp
Test Db
Heat, Cyclic)
Vibration
Shock
Bump
Long Life (Random Vibration)
Shock
Seismic
Altitude
Test Levels
± 8 kV
± 15 kV
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
95% (non-condensing),
55 °C (131 °F), 6 cycles
2 g @ 10-150 Hz
30 g @ 11 ms
10 g @ 16 ms
Category 1 Class B
Method A
12192 m (40000 ft)
@ 40 °C, 90 minutes
RUGGEDCOM RX1510
Installation Manual, 12/2019, C79000-G8976-1055-16
Severity
Levels
 
 
 
Class 2
Class 2
Class 1
 
 
Level 2
 