10 INSTALLATION
INSTALLATION
Product Specifications
The appearance and specifications listed in this manual may vary due to constant product improvements.
Gas Hob Models
Trivet
Wok Trivet
Top Plate
Product Dimension (W*D*H)
Cut Out Dimension (W*D*H)
Ignition device
Gas Connection
Electric supply
Burner Feature
ΣQn
Usage instructions
WARNING
• Do not modify this appliance.
• This appliance must be installed by an authorised technician or installer.
• Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and
the adjustment of the appliance are compatible.
• The adjustment conditions for this appliance are stated on the label (or data plate).
• This appliance is not connected to a combustion products evacuation device. It should be installed and
connected in accordance with current installation regulations. Particular attention should be given to the
relevant requirements regarding ventilaton.
• Before installing, turn off the gas and electricity supply to the appliance.
• All appliances containing any electrical components must be earthed.
• Ensure that the gas pipe and electrical cable are installed in such a way that they do not touch any parts
of the appliance which may become hot.
• Gas pipe or connector shouldn't be bent or blocked by any other appliances.
• Check the dimensions of the appliance as well as the dimensions of the gap to be cut in the kitchen unit.
• The panels located above the work surface, directly next to the appliance, must be made of non-
flammable material. Both the stratified surfacing and the glue used to secure it should be heat resistant,
to prevent deterioration.
• Turn on appliance tap and light each burners.
If burners shows any abnormalities, check the following :
− Burner cap positioned correctly
− Burner head positioned correctly
− Burner vertically aligned with nozzle
• A full operational test and a test for possible leakages must be carried out by the fitter after installation.
• The fiexible hose shall be fitted in such a way that it cannot come into contact with a moveable part of the
housing unit and does not pass through any space susceptible of becoming congested.
HJ747DAP
Cast Iron
Cast Iron
Ceramic Glass
760 mm X 510 mm X 105 mm
740 mm X 475 mm X 75 mm
Continuous Ignition Type
G1/2 thread
230 Vac / 50 Hz
Triple(2), Rapid(2)
11.1 kW
Correct Position
Incorrect Postion