Installation; Product Specifications; Usage Instructions - LG HJ747DAP Owner's Manual

Table of Contents

Advertisement

10 INSTALLATION

INSTALLATION

Product Specifications

The appearance and specifications listed in this manual may vary due to constant product improvements.
Gas Hob Models
Trivet
Wok Trivet
Top Plate
Product Dimension (W*D*H)
Cut Out Dimension (W*D*H)
Ignition device
Gas Connection
Electric supply
Burner Feature
ΣQn

Usage instructions

WARNING
• Do not modify this appliance.
• This appliance must be installed by an authorised technician or installer.
• Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and
the adjustment of the appliance are compatible.
• The adjustment conditions for this appliance are stated on the label (or data plate).
• This appliance is not connected to a combustion products evacuation device. It should be installed and
connected in accordance with current installation regulations. Particular attention should be given to the
relevant requirements regarding ventilaton.
• Before installing, turn off the gas and electricity supply to the appliance.
• All appliances containing any electrical components must be earthed.
• Ensure that the gas pipe and electrical cable are installed in such a way that they do not touch any parts
of the appliance which may become hot.
• Gas pipe or connector shouldn't be bent or blocked by any other appliances.
• Check the dimensions of the appliance as well as the dimensions of the gap to be cut in the kitchen unit.
• The panels located above the work surface, directly next to the appliance, must be made of non-
flammable material. Both the stratified surfacing and the glue used to secure it should be heat resistant,
to prevent deterioration.
• Turn on appliance tap and light each burners.
If burners shows any abnormalities, check the following :
− Burner cap positioned correctly
− Burner head positioned correctly
− Burner vertically aligned with nozzle
• A full operational test and a test for possible leakages must be carried out by the fitter after installation.
• The fiexible hose shall be fitted in such a way that it cannot come into contact with a moveable part of the
housing unit and does not pass through any space susceptible of becoming congested.
HJ747DAP
Cast Iron
Cast Iron
Ceramic Glass
760 mm X 510 mm X 105 mm
740 mm X 475 mm X 75 mm
Continuous Ignition Type
G1/2 thread
230 Vac / 50 Hz
Triple(2), Rapid(2)
11.1 kW
Correct Position
Incorrect Postion