Siemens PA-3 Manual

Power adapter, 50 hz/oil-filled
Table of Contents

Advertisement

Quick Links

PA-3 Power Adapter
(50 Hz/Oil-Filled)
Document No. 96A0260
Issued: December 15, 1999
Rev. B: May 16, 2001
Copyright ã 2001 by Siemens Airfield Solutions, Incorporated. All rights reserved.

Advertisement

Table of Contents
loading

Summary of Contents for Siemens PA-3

  • Page 1 PA-3 Power Adapter (50 Hz/Oil-Filled) Document No. 96A0260 Issued: December 15, 1999 Rev. B: May 16, 2001 Copyright ã 2001 by Siemens Airfield Solutions, Incorporated. All rights reserved.
  • Page 2: Record Of Changes

    PA-3 Power Adapter (50 Hz/Oil-Filled) Record of Changes Record of Changes Page Description EC No. Checked Approved Date Released new manual. 00350 12/15/99 Changed to new title page. Changed ADB to 00696 5/16/01 Siemens Airfield Solutions. Page ii  2001 Siemens Airfield Solutions, Incorporated...
  • Page 3: Table Of Contents

    2. Description ....................5 Introduction ..................5 PA-3 Power Adapter (50 Hz): Required Equipment......6 PA-3 Power Adapter (50 Hz) Specifications ........7 Load on CCR for Fully Loaded PA-3 Power Adapter (50 Hz) ..7 PA-3 Power Adapter (50 Hz) Technical Features......7 Construction ..................7 Weight....................8 Dimensions..................8...
  • Page 4 Figure 1. Siemens Airfield Solutions PA-3 Power Adapter (50 Hz/Oiled-Filled) ..............5 Figure 2. PA-3 Power Adapter (50 Hz) (Top View)........10 Figure 3. PA-3 Power Adapter (50 Hz) Spare Parts ........16 Figure 4. PA-3 Power Adapter (50 Hz) Wiring Schematic for Internally Lighted Wind Cones ..........17 List of Tables Table 1.
  • Page 5: Warranties

    Disclaimers This manual could contain technical inaccuracies or typographical errors. Siemens Airfield Solutions reserves the right to revise this manual from time to time in the contents thereof without obligation of Siemens Airfield Solutions to notify any person of such revision or change.
  • Page 6: Safety

    PA-3 Power Adapter (50 Hz/Oil-Filled) Safety PA-3 Power Adapter (50 Hz/Oil-Filled) This section contains general safety instructions for using your Siemens 1. Safety Airfield Solutions equipment. Some safety instructions may not apply to the equipment in this manual. Task- and equipment-specific warnings are included in other sections of this manual where appropriate.
  • Page 7: Qualified Personnel

    Unintended uses may result from taking the following actions: • making changes to equipment that have not been recommended or described in this manual or using parts that are not genuine Siemens Airfield Solutions replacement parts • failing to make sure that auxiliary equipment complies with approval agency requirements, local codes, and all applicable safety standards •...
  • Page 8: Installation

    WARNING: Failure to follow these safety procedures can result in personal injury or death. • Allow only qualified personnel to install Siemens Airfield Solutions and auxiliary equipment. Use only approved equipment. Using unapproved equipment in an approved system may void agency approvals.
  • Page 9: Action In The Event Of A System Or Component Malfunction

    Allow only qualified personnel to perform maintenance, troubleshooting, Maintenance and Repair and repair tasks. Only persons who are properly trained and familiar with Siemens Airfield Solutions equipment are permitted to service this equipment. • Always use safety devices when working on this equipment.
  • Page 10: Description

    See Figure 1. 2. Description Introduction This section describes the Siemens Airfield Solutions PA-3 series-to- regulated-voltage power adapter (50 Hz/oil-filled). Figure 1. Siemens Airfield Solutions PA-3 Power Adapter (50 Hz/Oiled-Filled) Page 5  2001 Siemens Airfield Solutions, Incorporated 96A0260B Issued 5/01...
  • Page 11: Power Adapter (50 Hz): Required Equipment

    PA-3 Power Adapter (50 Hz/Oil-Filled) Description Introduction The Siemens Airfield Solutions PA-3 power adapter (50 Hz) can be used to (contd.) power the L-807 internally lighted wind cone. Refer to Table 1 for power source and load capacity. NOTE: The Siemens Airfield Solutions power adapter is not approved for use with other manufacturers’...
  • Page 12: Power Adapter (50 Hz) Specifications

    B: Primary leads are 30 inches (76.20 cm) long. Secondary leads are 49 inches (124.46 cm) long. Construction The PA-3 power adapter (50 Hz) is watertight for direct earth burial, surface installation, or installation in an L-867 base (16-inch- [40.64-cm-] diameter base with a minimum height of 24 inches [50.8 cm]).
  • Page 13: Weight

    PA-3 Power Adapter (50 Hz/Oil-Filled) Description Weight Refer to Table 7 for the PA-3 power adapter (50 Hz) weight. Table 7. Weight Weight lb Weight kg 52.7208 Dimensions Refer to Table 8 for the PA-3 power adapter (50 Hz) dimensions.
  • Page 14: Installation

    This subsection describes installation information. Installation Method of Installation The watertight PA-3 power adapter (50 Hz) assembly is satisfactory for direct earth burial or above-surface installation. Install the PA-3 upright within 15 degrees of vertical. The preferred method of installation is to install the power adapter in a deep L-867 can.
  • Page 15: Power Adapter Connectors

    PA-3 Power Adapter (50 Hz/Oil-Filled) Installation Power Adapter Connectors See Figure 2. Refer to Table 10 for PA-3 power adapter (50 Hz) connectors. Table 10. PA-3 Power Adapter (50 Hz) Connectors Leads Lead Plug/Receptacle Note One 49-inch (124.46-cm) secondary lead Style 8 female receptacle (J2) Two 30-inch (76.20-cm) primary leads...
  • Page 16: Power Adapter (50 Hz) Installation On 6.6 A Series Circuit

    To connect the PA-3 power adapter (50 Hz) to a 6.6 A series circuit, perform the following procedure: If no direct interconnection is possible, cut the runway lighting circuit in accordance with proper airport installation authority regulations.
  • Page 17: Repair

    To access and service the components, follow the disassembling and assembling procedures in this section. Refer to Table 11 for replacement parts for the PA-3 power adapter (50 Hz). Table 11. PA-3 Power Adapter Replacement Parts Description...
  • Page 18: Assembling Pa-3 Oil-Filled Power Adapter

    After repairs, perform a systems check before installing the lid with the component package into the canister. Clean all gasket material from the lid and from the canister flange. To assemble the PA-3 oil-filled power adapter, perform the following Assembling PA-3 Oil-filled procedure: Power Adapter Clean all gasket material from the lid and from the canister flange.
  • Page 19 PA-3 Power Adapter (50 Hz/Oil-Filled) Repair Assembling PA-3 Oil-filled Make sure that all components are clean and free of any contaminants. Clean as necessary. If power cords or squeeze connectors have been Power Adapter (contd.) replaced, make sure the connector is sealed around the cord. Use any quality pipe dope on the connector threads.
  • Page 20: Parts

    PA-3 Power Adapter (50 Hz/Oil-Filled) Parts To order parts, call Siemens Airfield Solutions Customer Service or your 5. Parts local representative. Use this five-column parts list, and the accompanying illustration, to describe and locate parts correctly. Using the Illustrated Parts This subsection describes how to use the illustrated parts list covered later in this section.
  • Page 21: Power Adapter (50 Hz) Part Number

    PA-3 Power Adapter (50 Hz) The PA-3 power adapter (50 Hz) part number is 44B1545-1. Part Number PA-3 Power Adapter (50 Hz) See Figure 3. This subsection provides spare parts for the PA-3 power adapter (50 Hz). Spare Parts Item...
  • Page 22: Wiring Schematics

    L-823 1-Pole Female Connector L-823 2-Pole Male Connector 2.8-6.6 A Series Circuit Figure 4. PA-3 Power Adapter (50 Hz) Wiring Schematic for Internally Lighted Wind Cones Page 17  2001 Siemens Airfield Solutions, Incorporated 96A0260B Issued 5/01 All rights reserved...

Table of Contents