Connecting An Ac Power Supply - Siemens SIMATIC IFP2200 Operating Instructions Manual

Hide thumbs Also See for SIMATIC IFP2200:
Table of Contents

Advertisement

Installing and connecting the device
3.4 Connecting the device
3.4.3.3

Connecting an AC power supply

Note before connecting
NOTICE
Damage to the device in ungrounded supply systems
The device features a safety-certified power cable. Connect the device only to a grounding
socket. Operate the device only on grounded-neutral systems and not on impedance-
grounded systems such as IT networks.
NOTICE
Damage to the device due to connection to the wrong supply voltage
If the local supply voltage is incompatible with the permissible rated voltage for the device,
damage to the equipment may result.
Always make sure that the local supply voltage complies with the permissible rated voltage
for the device.
Regional information
Outside the United States and Canada, in regions with 230 V supply voltage:
If you do not use the safety-certified power cable, use a flexible, double-insulated power
supply cable (no single cables) with the following characteristics:
● At least 18 AWG (0.75 mm
● Grounded safety plug 15 A, 250 V
Note
Ensure that the cable set conforms to the respective national safety regulations and is
appropriately labeled.
For USA and Canada:
A CSA or UL-listed power supply cable must be used in the United States and Canada.
56
Industrial Flat Panel IFP1500, IFP1900, IFP2200, IFP1900 PRO, IFP2200 PRO, IFP1900 ETH, IFP2200 ETH
) conductor cross-section
2
Operating Instructions, 07/2016, A5E31298376-AF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ifp1900Simatic ifp1500Simatic ifp1900 ethSimatic ifp1900 proSimatic ifp2200 pro

Table of Contents