AMAX panel 2000 / AMAX panel 2000 EN
Figure 3.1 Wiring Diagram
3.1.1
Setting date and time
Set the date and time after powering up the system, otherwise Date and Time Default to
factory settings.
1.
2.
3.
Bosch Sicherheitssysteme GmbH
Z8
COM
Z7
Z6
COM
Z5
Z4
COM
Z3
Z2
COM
Z1
Y
G
B
R
GND
+12V
OC2
OC3
OC1
OC+
OC+
-
+
AC
AC
Enter the installer code +955 and press [#]. Two beeps sound, the STAY and AWAY
indicators flash and date + time is shown in the format YYMMDD HHMM.
After Date + Time is displayed, enter the year, month, day, hour and minute in YY, MM,
DD, HH, MM format and press [#]. Use 24:00 hour format when programming the hour of
the day. Two beeps sound and the STAY and AWAY indicators are deactivated. If a long
beep sounds, it indicates an erroneous entry of date and time.
If operation is not carried out within 240 seconds after entering the date and time setting
interface, the system will automatically exit from the setting.