en | System Informations 1
7

System Informations 1

7.1

Zone Processing when arming

When the system is armed, it will do the following process.
Arm precondition:
The system should be disarmed. Also the system should not be in programming mode and
walk test mode.
For arming the panel by keypad, force armed conditions are applied:
It can be armed with some zones unsealed when force arm is enabled for these zones, and
they are represented by slow flash zone indicators.
When the force arm of a zone is disabled, the zone must be in sealed status for arming the
panel.
Arm performance:
At the end of exit delay time, send the report to the configured destinations of the control
panel by setting location 138 or location 139 to 1.
It will not arm until the exit time is up. During the exit time, if the users disarmed the system,
then no report is sent.AWAY or STAY indicators are lit to indicate the ARM status.
Send the Battery Low report to the configured destinations of the control panel system if it
occurred by the setting of location 140.
NOTICE!
Single button arming in STAY Mode reports as User Code number 18.
Record the event in history.
AWAY ARM will monitor all zones except bypassed zones. STAY ARM will only monitor the
unsealed non interior zones.
Refer to Section 8.1.2 Zone programming, page 57 for different processes with different zone
types.
7.2

Zone Processing when disarming

Disarm precondition:
The system is armed.
Disarm performance:
Send the report to the configured destinations of the control panel system by the setting of
location 138 or location 139.
AWAY and STAY indicators are extinguished.
For zone not 24-Hour and keyswitch type, send the zone alarm/trouble restore report to the
system. Refer to Section 8.1.9 Zone Fault, page 63 for more information.
Record the event in history.
Restore the bypassed zones.
Unlock the lock out zones.24-Hour zones are always monitored regardless of arm or disarm if
it is not bypassed.
Refer to Section 8.1.2 Zone programming, page 57 for different processes with different zone
types.
7.3

Alarm processing

Alarm precondition:
F.01U.241.127 | V4 | 2011.12
Installation Manual
AMAX panel 2000 / AMAX panel 2000 EN