Upgrade Capability - HP 81110A Quick Start Manual

Pulse/pattern generators
Table of Contents

Advertisement

Introduction
General Information
NOTE:
The HP 81110A compared to the HP 81104A has better accuracy, up to
330 MHz clock rate, 800 ps typical edges at up to 3.8 V, and a timing
auto calibration.

Upgrade Capability

It is possible to upgrade the instruments with a second channel if only
one channel was originally ordered. There are two output channels avail-
able for the HP 81110A. The second channel that is installed must be the
same as channel one.
NOTE:
Mainframe
HP 81104A
HP 81110A
36
Please refer to the Reference Guide, part number 81110-91011,
for the command reference list.
Do not mix the output channels for the HP 81110A.
Table 1: Mainframe / Output Module Combinations
Module
HP 81105A
HP 81111A
HP 81112A
Introduction
Description
10V/ max. 80 MHz Output Channel
10V/ max. 165 MHz Output Channel
3.8V/ max. 330 MHz Output Channel
HP 81110/04A Quick Start