Repacking The Cisco Nexus 7010 Switch - Cisco Nexus 7000 Series Hardware Installation And Reference Manual

Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

Appendix E
Repacking the Cisco Nexus 7000 Series Switch for Shipment
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
When you are handling the Cisco Nexus 7000 Series switch or switch components, you must follow the
Caution
ESD protocol at all times to prevent ESD damage. This protocol includes but is not limited to wearing
an ESD wrist strap that you connect to the earth ground in the data center building.

Repacking the Cisco Nexus 7010 Switch

If you do not have the original packing materials for the Cisco Nexus 7010 switch that you are going to
repack, you must order another set of these materials (order part number is N7K-C7010-SHPPKG=).
Do not subject the pallet, switch, or package to water or moisture.
Caution
To repack the Cisco Nexus 7010 switch, follow these steps:
Turn the power switch on each power supply unit to STBY. The OUTPUT LED turns off.
Step 1
For each AC power supply unit, remove the power cords as follows:
Step 2
a.
b.
For each DC power supply unit, shut off the input power and remove the power cords as follows:
Step 3
a.
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Warning
Statement 1003
b.
c.
Warning
Hazardous voltage or energy may be present on DC power terminals. Always replace cover when
terminals are not in service. Be sure uninsulated conductors are not accessible when cover is in
place. Statement 1075
d.
OL-23069-06
1 lid
6 corro clips
Strapping
Remove the one or two power plugs from the power source. The Input LEDs turn off.
If you are removing a 6-kW AC power supply unit, unscrew the screw on the cable retention device
and pull the one or two plugs off the power supply unit.
Note
For a 7.5-kW power supply unit, you cannot remove the power cords from them because they
are permanently attached.
Turn off the DC input power by manually turning off each input circuit at its circuit breaker.
Verify that the input power is completely off by making sure that all of the LEDs on the DC power
supply units are off.
Detach each of the power cables from the powered down DC power source or DC power interface
unit (PIU).
For each of the power plugs attached to the DC power supply unit, completely unscrew the two
screws that hold it to the power supply unit and unplug it from the power supply unit.
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
Repacking the System Components
E-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nexus 7009Nexus 7018Nexus 7010

Table of Contents